Home › ENGINE · 1GR-FE › STARTING › STARTER (for 1.6 kW Type)

STARTER (for 1.6 kW Type) > INSPECTION

for Preparation Click here


NOTICE:
These tests must be performed within 3 to 5 seconds to prevent the coil from burning out.



1. INSPECT STARTER ASSEMBLY


    A075962E02
  1. Perform pull-in test.

    1. Disconnect the lead wire from terminal C.

    2. Connect the battery to the magnetic switch as shown in the illustration. Then check that the clutch pinion gear moves outward.
      If the result is not as specified, replace the repair service starter kit.



  1. Perform holding test.



      A075963E02
    1. With the battery connected as above with the clutch pinion gear out, disconnect the negative (-) lead from terminal C. Check that the pinion gear remains out.
      If the result is not as specified, replace the repair service starter kit.



    2. A075964E02
    3. Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns inward.
      If the result is not as specified, replace the repair service starter kit.



    A075965E02
  1. Perform operation test without load.

    1. Connect the field coil lead wire to terminal C.

      Torque:
      10 N*m{ 102 kgf*cm , 7 ft.*lbf }

    2. Mount the starter with a vise.

    3. Connect the battery and an ammeter to the starter as shown in the illustration.

    4. Check that the starter rotates smoothly and steadily while the pinion gear is moving out. Then measure the current.

      Standard current:
      90 A or less at 11.5 V

      If the result is not as specified, replace the starter assembly.



2. INSPECT STARTER ARMATURE ASSEMBLY


    A073983E12
  1. Check the resistance.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Segments
      Always
      Below 1 Ω

      If the result is not as specified, replace the armature assembly.



    2. A073984E09
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Segment - Coil core
      Always
      10 kΩ or higher

      If the result is not as specified, replace the armature assembly.

  1. Check the commutator surface for dirt or burns.
    If the surface is dirty or burnt, smooth the surface with 400-grit sandpaper or a lathe.



    A058584E15
  1. Using a vernier caliper, measure the protrusion length.

    Standard length:
    3.1 mm (0.122 in.)

    Maximum length:
    3.8 mm (0.150 in.)

    If the length is greater than the maximum, replace the armature assembly.



3. INSPECT STARTER COMMUTATOR END FRAME ASSEMBLY


    A076677E11
  1. Check the brush length.

    1. Using a vernier caliper, measure the brush length.

      Standard length:
      9.0 mm (0.354 in.)

      Minimum length:
      4.0 mm (0.158 in.)

      If the length is less than the minimum, replace the starter commutator end frame assembly.



    A076436E02
  1. Check the resistance.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Positive (+) brush - Negative (-) brush
      Always
      10 kΩ or higher

      If the result is not as specified, repair or replace the commutator end frame assembly.



4. INSPECT STARTER CENTER BEARING CLUTCH SUB-ASSEMBLY
  1. Check the gear teeth on the planetary gear, internal gear and starter clutch for wear or damage.
    If any of the gears is damaged, replace the center bearing clutch sub-assembly.



    A073987E04
  1. Check the starter clutch pinion gear.

    1. Hold the starter clutch and rotate the pinion gear clockwise, and check that it turns freely. Try to rotate the pinion gear counterclockwise and check that it locks.
      If necessary, replace the center bearing clutch sub-assembly.



5. INSPECT REPAIR SERVICE STARTER KIT


    A058586
  1. Check the plunger.

    1. Push in the plunger, and check that it returns quickly to its original position.
      If the result is not as specified, replace the repair service starter kit.



  1. Inspect the pull-in coil.



      A076126E02
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Terminals 50 - Terminal C
      Always
      Below 1 Ω

      If the result is not as specified, replace the repair service starter kit.



  1. Inspect the holding coil.



      A076129E02
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Terminal 50 - Switch body
      Always
      Below 2 Ω

      If the result is not as specified, replace the repair service starter kit.