Home › ENGINE · 1GR-FE › STARTING › STARTER (for 2.0 kW Type)

STARTER (for 2.0 kW Type) > INSPECTION

for Preparation Click here


NOTICE:
The following tests must be done within 3 to 5 seconds to prevent the coil from burning out.



1. INSPECT STARTER ASSEMBLY


    G036244E03
  1. Perform pull-in test.

    1. Remove the nut, then disconnect the field coil lead wire from terminal C.

    2. Connect the battery to the magnetic switch as shown in the illustration. Check that the clutch pinion gear moves outward.
      If the clutch pinion gear does not move, replace the magnet starter switch assembly.



    G036245E03
  1. Perform holding test.

    1. When the battery is connected as above with the clutch pinion gear out, disconnect the negative (-) lead from terminal C. Check that the pinion gear remains out.
      If the clutch pinion gear returns inward, replace the magnet starter switch assembly.



    G036246E03
  1. Inspect clutch pinion gear return.

    1. Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns inward.
      If the clutch pinion gear does not return inward, replace the magnet starter switch assembly.



    A075961E03
  1. Perform the operation test without load.

    1. Connect the field coil lead wire to terminal C.

      Torque:
      5.9 N*m{ 60 kgf*cm , 52 in.*lbf }

    2. Grip the starter in a vise.

    3. Connect the battery and an ammeter to the starter as shown.

    4. Check that the starter rotates smoothly and steadily with the clutch pinion gear extended.

    5. Check that the ammeter reads the specified current.

      Standard current:
      100 A or less at 11.5 V

      If the result is not as specified, replace the starter assembly.



2. INSPECT STARTER ARMATURE ASSEMBLY


    P010584E02
  1. Inspect the commutator for an open circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Commutator
      Always
      Below 1 Ω

      If the result is not as specified, replace the armature assembly.



    P010585E02
  1. Inspect the commutator for a short circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Commutator - Armature
      Always
      10 kΩ or higher

      If the result is not as specified, replace the armature assembly.

  1. Check the commutator surface for dirt and burns.
    If the surface is dirty or burnt, correct it with sandpaper (No. 400) or a lathe.



    P010586
  1. Inspect the commutator circle runout.

    1. Place the commutator on V-blocks.

    2. Using a dial indicator, measure the circle runout.

      Maximum circle runout:
      0.05 mm (0.00197 in.)

      If the runout is greater than the maximum, correct it with sandpaper (#400) or replace the armature assembly.



    P010587
  1. Using a vernier caliper, measure the commutator diameter.

    Standard diameter:
    35.0 mm (1.38 in.)

    Minimum diameter:
    34.0 mm (1.34 in.)

    If the diameter is less than the minimum, replace the armature assembly.



    ST00040
  1. Measure the undercut depth of the commutator.

    Standard undercut depth:
    0.7 mm (0.0276 in.)

    Minimum undercut depth:
    0.2 mm (0.00787 in.)

    If the undercut depth is less than the minimum, correct it with a hacksaw blade.

  1. Inspect the bearings.

    1. Check that the bearing rotates smoothly.



3. INSPECT BRUSH


    A062430E06
  1. Using a vernier caliper, measure the brush length.

    Standard brush length:
    15.0 mm (0.591 in.)

    Minimum brush length:
    9.0 mm (0.354 in.)

    If the length is less than the minimum, replace the brush holder and starter yoke assembly.



4. INSPECT STARTER BRUSH HOLDER ASSEMBLY


    A066735E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Positive brush holder - Negative brush holder
    Always
    10 kΩ or higher

    If the result is not as specified, replace the brush holder.



    ST00019E07
  1. Inspect the load of the brush spring.

    1. Take the pull scale reading immediately after the brush spring separates from the brush.

      Standard spring installed load:
      22 to 28 N (2 to 3 kgf, 4.8 to 6.2 lbf)

      Minimum spring installed load:
      13 N (1 kgf, 2.9 lbf)

      If the spring load is less than the minimum, replace the brush holder.



5. INSPECT STARTER YOKE ASSEMBLY


    P010588E03
  1. Inspect for an open circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Terminal C wire - Brush
      Always
      Below 1 Ω

      If the result is not as specified, replace the starter yoke assembly.



    2. A076125E02
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester connection
      Condition
      Specified Condition
      Shunt coil terminal (A) - Shunt coil terminal (B)
      20°C (68°F)
      1.5 to 1.9 Ω

      If the result is not as specified, replace the starter yoke assembly.



6. INSPECT STARTER CLUTCH SUB-ASSEMBLY


    P010821E09
  1. Check that the starter clutch cannot be rotated counterclockwise, and can be rotated clockwise.
    If the starter clutch is not as specified, replace the starter clutch sub-assembly.



7. INSPECT MAGNET STARTER SWITCH ASSEMBLY


    A076119E03
  1. Inspect the pull-in coil.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Terminals 50 - Terminal C
      Always
      Below 1 Ω

      If the result is not as specified, replace the magnet starter switch assembly.



    A076120E03
  1. Inspect the holding coil.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      Terminal 50 - Switch body
      Always
      Below 2 Ω

      If the result is not as specified, replace the magnet starter switch assembly.