Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 1GR-FE ENGINE CONTROL SYSTEM

1GR-FE ENGINE CONTROL SYSTEM > SERVICE DATA



Camshaft timing oil control valve:

Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
6.9 to 7.9 Ω


Crankshaft position sensor:

Tester Connection
Condition
Specified Condition
1 - 2
Cold
1630 to 2740 Ω
Hot
2065 to 3225 Ω


Engine coolant temperature sensor:

Tester Connection
Condition
Specified Condition
1 - 2
Approx. 20°C (68°F)
2.32 to 2.59 kΩ
Approx. 80°C (176°F)
0.310 to 0.326 kΩ


Throttle body:

Tester Connection
Condition
Specified Condition
2 (M+) - 1 (M-)
20°C (68°F)
0.3 to 100 Ω
5 (VC) - 3 (E2)
20°C (68°F)
1.2 to 3.2 kΩ


Knock sensor:

Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
120 to 280 kΩ


Ignition relay No. 2:

Tester Connection
Condition
Specified Condition
IG2 MAIN fuse
Always
Below 1 Ω
1C-1 - 1B-8
When battery voltage is not applied to terminals 1B-6 and 1B-7
10 kΩ or higher
When battery voltage is applied to terminals 1B- 6 and 1B-7
Below 1 Ω


EFI relay:

Tester Connection
Condition
Specified Condition
EFI No. 1 fuse
Always
Below 1 Ω
1C-1 - 1B-4
When battery voltage is not applied to terminals 1B-2 and 1B-3)
10 kΩ or higher
When battery voltage is applied to terminals 1B- 2 and 1B-3)
Below 1 Ω
1C-1 - 1B-5
When battery voltage is not applied to terminals 1B-2 and 1B-3)
10 kΩ or higher
When battery voltage is applied to terminals 1B- 2 and 1B-3)
Below 1 Ω


Circuit opening relay:

Tester Connection
Condition
Specified Condition
3 - 5
When battery voltage is not applied to terminals 1 and 2
10 kΩ or higher
When battery voltage is applied to terminals 1 and 2
Below 1 Ω


Air fuel ration sensor (for Bank 1 sensor 1):

Tester Connection
Condition
Specified Condition
1 (HT1A) - 2 (+B)
20°C (68°F)
1.8 to 3.4 Ω


Air fuel ration sensor (for Bank 2 sensor 1):

Tester Connection
Condition
Specified Condition
1 (HT2A) - 2 (+B)
20°C (68°F)
1.8 to 3.4 Ω


Heated oxygen sensor (for Bank 1 sensor 2):

Tester Connection
Condition
Specified Condition
1 (HT1B) - 2 (+B)
20°C (68°F)
11 to 16 Ω


Heated oxygen sensor (for Bank 2 sensor 2):

Tester Connection
Condition
Specified Condition
1 (HT2B) - 2 (+B)
20°C (68°F)
11 to 16 Ω


A/F sensor heater relay:

Tester Connection
Condition
Specified Condition
A/F fuse
Always
Below 1 Ω
1C-1 - 1A-4
When battery voltage is not applied to terminals 1A-2 and 1A-3
10 kΩ or higher
When battery voltage is applied to terminals 1A- 2 and 1A-3
Below 1 Ω