CAN COMMUNICATION SYSTEM > Open in CAN Main Wire |
| Symptom | Trouble Area |
| Resistance between terminals 6 (CANH) and 14 (CANL) of DLC3 is 69 Ω or higher. |
|

| 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
| NEXT | |
| 2.CHECK DLC3 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Measured Resistance | Proceed to |
| J17-6 (CANH) - J17-14 (CANL) | Ignition switch OFF | 54 to 69 Ω | OK |
| 69 Ω or higher | NG |
|
| ||||
| OK | |
| 3.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - ECM) |
![]() |
Disconnect the J94 No. 1 junction connector connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J94-1 (CANH) - J94-2 (CANL) | Ignition switch OFF | 108 to 132 Ω |
|
| ||||
| OK | |
| 4.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - COMBINATION METER ECU) |
![]() |
Disconnect the J84 No. 1 junction connector connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J84-1 (CANH) - J84-2 (CANL) | Ignition switch OFF | 108 to 132 Ω |
|
| ||||
| OK | ||
| ||
| 5.CONNECT CONNECTOR |
Reconnect the J94 No. 1 junction connector connector.
| NEXT | |
| 6.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - ECM) |
![]() |
Disconnect the J92 No. 2 junction connector connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J92-1 (CANH) - J92-2 (CANL) | Ignition switch OFF | 108 to 132 Ω |
|
| ||||
| OK | |
| 7.CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR) |
![]() |
Disconnect the J93 No. 2 junction connector connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J93-1 (CANH) - J93-2 (CANL) | Ignition switch OFF | 108 to 132 Ω |
|
| ||||
| OK | ||
| ||
| 8.CONNECT CONNECTOR |
Reconnect the J92 No. 2 junction connector connector.
| NEXT | |
| 9.CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM - NO. 2 JUNCTION CONNECTOR) |
![]() |
Disconnect the A24 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A24-10 (CANH) - A24-11 (CANL) | Ignition switch OFF | 108 to 132 Ω |
| Result | Proceed to |
| OK (for 1GR-FE) | A |
| OK (for 2UZ-FE) | B |
| OK (for 3UR-FE) | C |
| OK (for 3UR-FBE) | D |
| NG | E |
|
| ||||
|
| ||||
|
| ||||
|
| ||||
| A | ||
| ||
| 10.CONNECT CONNECTOR |
Reconnect the J84 No. 1 junction connector connector.
| NEXT | |
| 11.CHECK FOR OPEN IN CAN BUS MAIN WIRE (COMBINATION METER ECU - NO. 1 JUNCTION CONNECTOR) |
![]() |
Disconnect the J28 combination meter ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| J28-33 (CANH) - J28-34 (CANL) | Ignition switch OFF | 108 to 132 Ω |
|
| ||||
| OK | ||
| ||