AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > DATA LIST / ACTIVE TEST |
| READ DATA LIST |
Warm up the engine.
Turn the ignition switch OFF.
Connect the Techstream to the DLC3.
Turn the ignition switch ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / (desired menu) / Data List.
According to the display on the Techstream, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) | Actual room temperature for front seat is displayed | Open in circuit: -6.5°C (20.3°F) Short in circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature is displayed | Open in circuit: -23.3°C (-9.94°F) Short in circuit: 65.95°C (150.71°F) |
| Evaporator Fin Thermistor | Evaporator fin thermistor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature is displayed | Open in circuit: -29.7°C (-21.46°F) Short in circuit: 59.55°C (139.19°F) |
| Solar Sensor (D Side) | Driver side solar sensor / Min.: 0, Max.: 255 | Driver side solar sensor voltage increases as brightness increases | Open in circuit: 0 Short in circuit: 255 |
| Solar Sensor (P Side) | Passenger side solar sensor / Min.: 0, Max.: 255 | Passenger side solar sensor voltage increases as brightness increases | Open in circuit: 0 Short in circuit: 255 |
| Engine Coolant Temp | Engine coolant temperature / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature is displayed while engine is warmed up | - |
| Set Temperature (D Side) | Driver side set temperature / Min.: 0, Max.: 255 | Driver side actual set temperature is displayed | - |
| Set Temperature (P Side) | Passenger side set temperature / Min.: 0, Max.: 255 | Passenger side actual set temperature is displayed | - |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0 level, Max.: 31 level | Increases in range between 0 and 31 as blower motor speed increases | - |
| Adjusted Ambient Temperature | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) | Adjusted ambient temperature is displayed | - |
| Air Mix Servo Targ Pulse (D) | Driver side air mix servo motor target pulse / Min.: 5, Max.: 104 | MAX. COLD: 5 (pulse) MAX. HOT: 104 (pulse) | - |
| Air Mix Servo Targ Pulse (P) | Passenger side air mix servo motor target pulse / Min.: 6, Max.: 105 | MAX. COLD: 105 (pulse) MAX. HOT: 6 (pulse) | - |
| Air Outlet Servo Pulse (D) | Driver side air outlet servo motor target pulse / Min.: 9, Max.: 97 | FACE: 9 (pulse) B/L: 32 (pulse) FOOT: 56 (pulse) FOOT/DEF: 83 (pulse) DEF: 97 (pulse) | - |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse / Min.: 7, Max.: 28 | REC: 7 FRS: 28 | - |
| Cool Air Bypass Pulse | Cool air bypass servo motor target pulse / Min.: 8, Max.: 50 | Open: 8 (pulse) Close: 50 (pulse) | - |
| Shift Set Temperature | Shift set temperature / +2 C, +1 C, Normal, -1 C, -2 C | Customized value will be displayed | - |
| Air Inlet Mode | Air inlet mode / Auto, Manual | Customized value will be displayed | - |
| Compressor Mode | Compressor mode / Auto, Manual | Customized value will be displayed | - |
| Compressor/DEF Mode | Compressor/DEF mode / Link, Normal | Customized value will be displayed | - |
| Foot/DEF Auto Mode | FOOT/DEF auto mode / ON, OFF | Customized value will be displayed | - |
| Foot/DEF Auto Blow Up | FOOT/DEF auto blower up function / ON, OFF | Customized value will be displayed | - |
| Ambient Temperature Shift | Ambient temperature shift / +3 C, +2 C, +1 C, Normal, -1 C, -2 C, -3 C | Customized value will be displayed | - |
| Destination | Destination / DOMEST, USA, EUROPE, AUSTRAL, MIDEAST, NO INFO | Changes value with destinations | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0, Max.: 255 | Number of DTCs will be displayed | - |
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/C Signal | Air conditioning switch signal / ON or OFF | ON: Air conditioning ON OFF: Air conditioning OFF | - |
| PERFORM ACTIVE TEST |
Connect the Techstream to the DLC3.
Turn the ignition switch ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
According to the display on the Techstream, perform the "Active Test".
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Magnetic Clutch Relay | Magnetic clutch relay | ON or OFF | - |
| Air Mix Servo Targ Pulse (D) | Driver side air mix servo motor pulse | Min.: 5, Max.: 104 | - |
| Air Mix Servo Targ Pulse (P) | Passenger side air mix servo motor pulse | Min.: 6, Max.: 105 | - |
| Air Outlet Servo Pulse (D) | Driver side air outlet servo motor pulse | Min.: 9, Max.: 97 | - |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse | Min.: 7, Max.: 28 | - |
| Cool Air Bypass Pulse | Driver side cool air bypass pulse | Min.: 8, Max.: 50 | - |