Home
›
ENGINE ยท 1GR-FE
›
EMISSION CONTROL
›
PCV VALVE
PCV VALVE > INSTALLATION
for Preparation
Click here
1. INSTALL VENTILATION VALVE SUB-ASSEMBLY
Apply adhesive to 2 or 3 threads.
Adhesive:
Toyota Genuine Adhesive 1324, Three Bond 1324 or equivalent
Install the ventilation valve.
Torque:
27 N*m{ 275 kgf*cm , 20 ft.*lbf }
2. CONNECT VENTILATION HOSE