Home › ENGINE · 1GR-FE › EMISSION CONTROL › AIR PUMP

AIR PUMP > INSPECTION

for Preparation Click here



1. INSPECT AIR PUMP


A158408E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    0.4 to 1.0 Ω
    1 - Body ground
    Always
    10 kΩ or higher
    2 - Body ground

    If the result is not as specified, replace the air pump.



    A158406E02
  1. Check operation of the air pump.

    1. Check that air does not flow from port A to port B.
      If the result is not as specified, replace the air pump.



    2. A158407E02
    3. Apply battery voltage across terminals 1 and 2.

      NOTICE:
      1. Do not operate the air pump continuously for 2 minutes or more.
      2. When operating the air pump, wait 5 minutes until the pump has cooled down between each operation. If the pump has not cooled down sufficiently, the motor will burn out.

    4. Check that air flows from port A to port B.
      If the result is not as specified, replace the air pump.