VALVE BODY ASSEMBLY > INSPECTION |
| 1. INSPECT SHIFT SOLENOID VALVE SR |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Solenoid Connector (SR) - Solenoid Body (SR) | 20°C (68°F) | 11 to 15 Ω |
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.
| 2. INSPECT SHIFT SOLENOID VALVE SLU |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Terminal 1 of shift solenoid valve SLU - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.
| 3. INSPECT SHIFT SOLENOID VALVE SL2 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Terminal 1 of shift solenoid valve SL2 - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.
| 4. INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Terminal 1 of shift solenoid valve SLT - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.
| 5. INSPECT SHIFT SOLENOID VALVE SL1 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Terminal 1 of shift solenoid valve SL1 - terminal 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.
| 6. INSPECT SHIFT SOLENOID VALVE S1 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Solenoid Connector (S1) - Solenoid Body (S1) | 20°C (68°F) | 11 to 15 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.
| 7. INSPECT SHIFT SOLENOID VALVE S2 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Solenoid Connector (S1) - Solenoid Body (S1) | 20°C (68°F) | 11 to 15 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.