VALVE BODY ASSEMBLY > INSPECTION

for Preparation Click here



1. INSPECT SHIFT SOLENOID VALVE SR


C158386E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (SR) - Solenoid Body (SR)
    20°C (68°F)
    11 to 15 Ω

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes operating noise.

    If the result is not as specified, replace the solenoid valve.



2. INSPECT SHIFT SOLENOID VALVE SLU


C162477E04
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Terminal 1 of shift solenoid valve SLU - terminal 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes operating noise.

    If the result is not as specified, replace the solenoid valve.



3. INSPECT SHIFT SOLENOID VALVE SL2


C151311E13
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Terminal 1 of shift solenoid valve SL2 - terminal 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes operating noise.

    If the result is not as specified, replace the solenoid valve.



4. INSPECT SHIFT SOLENOID VALVE SLT


C162477E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Terminal 1 of shift solenoid valve SLT - terminal 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes operating noise.

    If the result is not as specified, replace the solenoid valve.



5. INSPECT SHIFT SOLENOID VALVE SL1


C151311E15
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Terminal 1 of shift solenoid valve SL1 - terminal 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes operating noise.

    If the result is not as specified, replace the solenoid valve.



6. INSPECT SHIFT SOLENOID VALVE S1


C159062E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (S1) - Solenoid Body (S1)
    20°C (68°F)
    11 to 15 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes operating noise.

    If the result is not as specified, replace the solenoid valve.



7. INSPECT SHIFT SOLENOID VALVE S2


C158386E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    Solenoid Connector (S1) - Solenoid Body (S1)
    20°C (68°F)
    11 to 15 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check that the valve moves and makes an operating noise.

    OK:
    Valve moves and makes operating noise.

    If the result is not as specified, replace the solenoid valve.