SHIFT LEVER ASSEMBLY (for Column Shift Type) > INSPECTION |
| 1. INSPECT COLUMN SHIFT SHIFT LEVER SUB-ASSEMBLY |
![]() |
Disconnect the transmission control switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 6 (IG) - 13 (S) | Shift lever position S, "+" and "-" | Below 1 Ω |
| 5 (SFTU) - 11 (E) | Shift lever position continuously shifted to "+" (Up-shift) | |
| 4 (SFTD) - 11 (E) | Shift lever position continuously shifted to "-" (Down-shift) | |
| 6 (IG) - 13 (S) | Shift lever position not on S, "+" and "-" | 10 kΩ or higher |
| 5 (SFTU) - 11 (E) | Shift lever position S | |
| 4 (SFTD) - 11 (E) |