Home › BODY › SLIDING ROOF › SLIDING ROOF SYSTEM

SLIDING ROOF SYSTEM > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST

HINT:
Using the Techstream to read the Data List allows values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch ON.

  3. Turn the Techstream on.

  4. Enter the following menus:
    Select: Body Electrical / Sliding Roof / Data List.

  5. According to the display on tester, read the "Data List".

    Sliding Roof 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Open Switch
    Slide switch open signal/ON or OFF
    ON: SLIDE switch is pressed to open
    OFF: SLIDE switch is not pressed to open
    -
    Close Switch
    Slide switch close signal/ON or OFF
    ON: SLIDE switch is pressed to close
    OFF: SLIDE switch is not pressed to close
    -
    Up Switch
    Tilt switch up signal/ON or OFF
    ON: TILT switch is pressed to up
    OFF: TILT switch is not pressed to up
    -
    Down Switch
    Tilt switch down signal/ON or OFF
    ON: TILT switch is pressed to down
    OFF: TILT switch is not pressed to down
    -
    Hall IC1 Status
    Sliding roof operation signal/NORMAL or LOCK
    NORMAL: Sliding roof motor is operating
    LOCK: Sliding roof motor is not operating
    -
    Hall IC1 Pulse
    Sliding roof operation signal/LO or HI
    LO: Sliding roof motor is not operating
    HI: Sliding roof motor is operating
    -
    Hall IC2 Status
    Sliding roof operation signal/NORMAL or LOCK
    NORMAL: Sliding roof motor is operating
    LOCK: Sliding roof motor is not operating
    -
    Hall IC2 Pulse
    Sliding roof operation signal/LO or HI
    LO: Sliding roof motor is not operating
    HI: Sliding roof motor is operating
    -
    Ignition (Direct Signal)
    Ignition switch signal/ON or OFF
    ON: Ignition switch ON
    OFF: Ignition switch off
    -
    Ignition (MPX)
    Ignition switch signal (MPX signal)/ON or OFF
    ON: Ignition switch ON
    OFF: Ignition switch off
    -
    Door Courtesy
    Driver's door courtesy light switch signal/ON or OFF
    ON: Driver's door is open
    OFF: Driver's door is closed
    -
    Door Key Close Operation
    Key-linked sliding roof open signal/ON or OFF
    ON: Door key cylinder is turned to UNLOCK position using key
    OFF: Door key cylinder is not turned to UNLOCK
    -
    Door Key Open Operation
    Key-linked sliding roof close signal/ON or OFF
    ON: Door key cylinder is turned to LOCK position using key
    OFF: Door key cylinder is not turned to LOCK
    -
    Key Off Permission
    Key-off sliding roof operation permit signal/ON or OFF
    ON: Driver's side door is not closed within 45 sec after ignition switch is turned off
    OFF: Any status except "ON" status
    -
    Door Key Related (Open)
    Key-linked sliding roof open operation status/Avail or Not Avail
    Avail: Key-linked sliding roof open operation is available
    Not Avail: Key-linked sliding roof open operation is not available
    -
    Door Key Related (Close)
    Key-linked sliding roof close operation status/Avail or Not Avail
    Avail: Key-linked sliding roof close operation is available
    Not Avail: Key-linked sliding roof close operation is not available
    -
    Door Key Related Operation
    Direction for key-linked operation/Tilt or Slide
    Tilt: Key-linked sliding roof operation operates tilt up or down
    Slide: Key-linked sliding roof operation operates slide open or close
    -
    Down Switch Failure (Current)
    Down switch failure signal (Current)/ON or OFF
    ON: Sliding roof tilt down signal failure (Current)
    OFF: Sliding roof tilt down signal not fail (Current)
    -
    Up Switch Failure (Current)
    Up switch failure signal (Current)/ON or OFF
    ON: Sliding roof tilt up signal failure (Current)
    OFF: Sliding roof tilt up signal not fail (Current)
    -
    Close Switch Failure (Current)
    Close switch failure signal (Current)/ON or OFF
    ON: Sliding roof close signal failure (Current)
    OFF: Sliding roof close signal not fail (Current)
    -
    Open Switch Failure (Current)
    Open switch failure signal (Current)/ON or OFF
    ON: Sliding roof open signal failure (Current)
    OFF: Sliding roof open signal not fail (Current)
    -
    Down Switch Failure (Past)
    Down switch failure signal (Past)/ON or OFF
    ON: Sliding roof tilt down signal failure (Past)
    OFF: Sliding roof tilt down signal not fail (Past)
    -
    Up Switch Failure (Past)
    Up switch failure signal (Past)/ON or OFF
    ON: Sliding roof tilt up signal failure (Past)
    OFF: Sliding roof tilt up signal not fail (Past)
    -
    Close Switch Failure (Past)
    Close switch failure signal (Past)/ON or OFF
    ON: Sliding roof close signal failure (Past)
    OFF: Sliding roof close signal not fail (Past)
    -
    Open Switch Failure (Past)
    Open switch failure signal (Past)/ON or OFF
    ON: Sliding roof open signal failure (Past)
    OFF: Sliding roof open signal not fail (Past)
    -


ACTIVE TEST

HINT:
Using the Techstream to perform Active Test allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Test early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Test.

  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch ON.

  3. Turn the Techstream on.

  4. Enter the following menus:
    Select: Body Electrical / Sliding Roof / Active Test.

  5. According to the display on tester, perform the "Active Test".

    Sliding Roof 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Slide Roof
    Operate sliding roof SLIDE CLOSE/TILT UP or SLIDE OPEN/TILT DOWN
    CLOS/UP: Sliding roof SLIDE CLOSE or TILT UP operation occurs
    OPN/DWN: Sliding roof SLIDE OPEN or TILT DOWN operation occurs
    OFF: Sliding roof is not operating
    -