VALVE BODY ASSEMBLY > INSPECTION |
| 1. INSPECT SHIFT SOLENOID VALVE SL1 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) with a 21 W bulb → Terminal 1 Battery negative (-) → Terminal 2 | Valve moves and makes an operating noise |
| 2. INSPECT SHIFT SOLENOID VALVE S1 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Shift solenoid valve S1 connector Battery negative (-) → Shift solenoid valve S1 body | Valve moves and makes an operating noise |
| 3. INSPECT SHIFT SOLENOID VALVE S2 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Shift solenoid valve S2 connector Battery negative (-) → Shift solenoid valve S2 body | Valve moves and makes an operating noise |
| 4. INSPECT SHIFT SOLENOID VALVE S3 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Shift solenoid valve S3 connector Battery negative (-) → Shift solenoid valve S3 body | Valve moves and makes an operating noise |
| 5. INSPECT SHIFT SOLENOID VALVE S4 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Shift solenoid valve S4 connector Battery negative (-) → Shift solenoid valve S4 body | Valve moves and makes an operating noise |
| 6. INSPECT SHIFT SOLENOID VALVE SL2 |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) with a 21 W bulb → Terminal 1 Battery negative (-) → Terminal 2 | Valve moves and makes an operating noise |
| 7. INSPECT SHIFT SOLENOID VALVE SR |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve SR connector terminal - Shift solenoid valve SR body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Shift solenoid valve SR connector Battery negative (-) → Shift solenoid valve SR body | Valve moves and makes an operating noise |
| 8. INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) with a 21 W bulb → Terminal 2 Battery negative (-) → Terminal 1 | Valve moves and makes an operating noise |
| 9. INSPECT SHIFT SOLENOID VALVE SLU |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Battery positive (+) with a 21 W bulb → Terminal 2 Battery negative (-) → Terminal 1 | Valve moves and makes an operating noise |