DTC P0112 Intake Air Temperature Circuit Low Input |
DTC P0113 Intake Air Temperature Circuit High Input |

| DTC Code | DTC Detection Condition | Trouble Area |
| P0112 | Short in IAT sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0113 | Open in IAT sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) or higher | Short circuit |
| Related DTCs | P0112: IAT sensor range check (Low voltage) P0113: IAT sensor range check (High voltage) |
| Required Sensors/Components (Main) | IAT sensor |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 0.5 seconds |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 8V or more |
| Ignition switch | ON |
| Starter | OFF |
| IAT sensor voltage [IAT] | Less than 0.18 V [More than 128°C (262.4°F)] |
| IAT sensor voltage [IAT] | More than 4.91 V [Less than -55°C (-67°F)] |
| IAT sensor voltage [IAT] | 0.18 to 4.91 V [-55 to 128°C (-67 to 262.4°F)] |

| Tester Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.READ VALUE USING TECHSTREAM (INTAKE AIR TEMPERATURE) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.
Read the value displayed on the Techstream.
| Temperature Displayed | Proceed to |
| -40°C (-40°F) | A |
| 140°C (284°F) or higher | B |
| Same as actual IAT | C |
|
| ||||
|
| ||||
| A | |
| 2.READ VALUE USING TECHSTREAM (CHECK FOR OPEN IN WIRE HARNESS) |
![]() |
Disconnect the D7 MAF meter connector.
Connect terminals 4 (THA) and 5 (E2) of the MAF meter wire harness side connector.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.
Read the value displayed on the Techstream.
|
| ||||
| OK | ||
| ||
| 3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the D7 MAF meter connector.
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-4 (THA) - D74-73 (THA) | Always | Below 1 Ω |
| D7-5 (E2) - D74-97 (ETHW) | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 4.READ VALUE USING TECHSTREAM (CHECK FOR SHORT IN WIRE HARNESS) |
![]() |
Disconnect the D7 MAF meter connector.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.
Read the value displayed on the Techstream.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the D7 MAF meter connector.
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-4 (THA) or D74-73 (THA) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||