Home › ENGINE ยท 1GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0441    Evaporative Emission Control System Incorrect Purge Flow

for Preparation Click here


DTC SUMMARY


DTC No.
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P0441
Purge VSV (Vacuum Switching Valve) stuck open
Leak detection pump creates negative pressure (vacuum) in the EVAP system and the EVAP system pressure is measured. Reference pressure is measured at the start and end of the leak check.
If the stabilized pressure is higher than [second reference pressure x 0.2], the ECM determines that the purge VSV is stuck open.
  1. Purge VSV
  2. Connector/wire harness (Purge VSV - ECM)
  3. ECM
  4. Canister pump module
  5. Leakage from EVAP system
While ignition switch off
2 trip
Purge VSV stuck closed
After the EVAP leak check is performed, the purge VSV is turned ON (open) and outside air is introduced into the EVAP system. Reference pressure is measured at the start and end of the check.
If the pressure does not return to near atmospheric pressure, the ECM determines that the purge VSV is stuck closed.
  1. Purge VSV
  2. Purge line
  3. Connector/wire harness (Purge VSV - ECM)
  4. ECM
  5. Canister pump module
  6. Canister (filter inside canister clogged)
  7. Leakage from EVAP system
While ignition switch off
2 trip
Purge flow
While the engine is running, the following conditions are successively met:
  1. Negative pressure is not created in the EVAP system when the purge VSV is turned ON (open).
  2. EVAP system pressure change is less than 0.5 kPa-g (3.75 mmHg-g) when the vent valve is turned ON (closed).
  3. Atmospheric pressure change before and after the purge flow monitor is less than 0.1 kPa-g (0.75 mmHg-g).
  1. Purge VSV
  2. Purge line
  3. Connector/wire harness (Purge VSV - ECM)
  4. Leakage from EVAP line (Purge VSV - Intake manifold)
  5. Canister (filter inside canister clogged)
  6. ECM
While engine running
2 trip

DESCRIPTION

Refer to EVAP (Evaporative Emission) System .

INSPECTION PROCEDURE

Refer to EVAP System .

MONITOR DESCRIPTION

The two monitors, Key-off and Purge Flow, are used to detect malfunctions relating to DTC P0441. The Key-off monitor is initiated by the ECM internal timer, known as the soak timer, 5 hours* after the ignition switch is turned off. The purge flow monitor runs while the engine is running.

  1. Key-off Monitor
    5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

    HINT:
    *: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


    Sequence
    Operation
    Description
    Duration
    -
    ECM activation
    Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off.
    -
    A
    Atmospheric pressure measurement
    Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
    If pressure in EVAP system not between 76 kPa-a and 110 kPa-a (570 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
    60 seconds
    B
    First reference pressure measurement
    In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice, and then ECM checks if leak detection pump and vent valve operate normally.
    360 seconds
    C
    EVAP system pressure measurement
    Vent valve turned ON (closed) to shut EVAP system.
    Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
    Write down measured value as it will be used in leak check.
    If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
    15 minutes*
    D
    Purge VSV monitor
    Purge VSV opened, and then EVAP system pressure measured by ECM.
    Large increase indicates normality.
    10 seconds
    E
    Second reference pressure measurement
    After second reference pressure measurement, leak check performed by comparing first and second reference pressure measurements.
    If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
    60 seconds
    -
    Final check
    Atmospheric pressure measured, and then monitoring result recorded by ECM.
    -
    *: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.


    A112612E31


    1. Purge VSV stuck open
      In operation C, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The EVAP system pressure is then measured by the ECM using the canister pressure sensor. If the stabilized system pressure is higher than [second reference pressure x 0.2], the ECM interprets this as the purge VSV (Vacuum Switching Valve) being stuck open. The ECM illuminates the MIL and stores the DTC (2 trip detection logic).


      A108008E67


    2. Purge VSV stuck closed
      In operation D, the canister pressure sensor measures the EVAP system pressure. The pressure measurement for the purge VSV monitor is begun when the purge VSV is turned ON (open) after the EVAP leak check. When the measured pressure indicates an increase of 0.3 kPa-g (2.25 mmHg-g) or more, the purge VSV is functioning normally. If the pressure does not increase, the ECM interprets this as the purge VSV being stuck closed. The ECM illuminates the MIL and stores the DTC (2 trip detection logic).


      A106059E80


  2. Purge Flow Monitor


    A112640E94

    The purge flow monitor consists of 2 monitors. The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.
  1. The 1st monitor
    While the engine is running and the purge VSV is ON (open), the ECM monitors the purge flow by measuring the EVAP pressure change. If negative pressure is not created, the ECM begins the 2nd monitor.
  2. The 2nd monitor
    The vent valve is turned ON (closed) and the EVAP pressure is then measured. If the variation in the pressure is less than 0.15 kPa-g (1.12 mmHg-g), the ECM interprets this as the purge VSV being stuck closed, and then illuminates the MIL and stores DTC P0441 (2 trip detection logic).
Atmospheric pressure check:
In order to ensure reliable malfunction detection, the variation between the atmospheric pressure, before and after conduction of the purge flow monitor, is measured by the ECM.

MONITOR STRATEGY


Related DTCs
P0441: Purge VSV stuck open/closed
P0441: Purge flow
Required Sensors/Components
Purge VSV
Canister pump module
Frequency of Operation
Once per driving cycle
Duration
Within 20 minutes (varies with amount of fuel in tank): Purge VSV stuck open/closed
Within 10 minutes: Purge flow
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


All 
Monitor runs whenever following DTCs not stored
P0452, P0453 (EVAP system)

Key-off Monitor 
Atmospheric pressure
70 to 110 kPa-a (525 to 825 mmHg-a)
Battery voltage
10.5 V or higher
Vehicle speed
Less than 4 km/h (2.5 mph)
Ignition switch
Off
Time after key-off
5, 7 or 9.5 hours
Purge VSV
Not operated by scan tool
Vent valve
Not operated by scan tool
Leak detection pump
Not operated by scan tool
Both of following conditions met before key-off
Conditions 1 and 2
1. Duration that vehicle driven
5 minutes or more
2. EVAP purge operation
Performed
Engine coolant temperature
4.4 to 35°C (40 to 95°F)
Intake air temperature
4.4 to 35°C (40 to 95°F)

Purge Flow Monitor 
Engine
Running
Engine coolant temperature
4.4°C (40°F) or higher
Intake air temperature
4.4°C (40°F) or higher
Purge VSV
Not operated by scan tool
EVAP system check
Not operated by scan tool
Atmospheric pressure
76 to 111 kPa-a (570 to 835 mmHg-a)
Battery voltage
10 V or higher
Purge duty cycle
8% or more

TYPICAL MALFUNCTION THRESHOLDS


Purge VSV Stuck Open 
EVAP pressure when vacuum introduction complete
Reference pressure x 0.2 or higher

Purge VSV Stuck Closed 
EVAP pressure change after purge VSV ON (open)
Less than 0.3 kPa-g (2.25 mmHg-g)

Purge Flow 
Both of following conditions met
Conditions 1 and 2
1. EVAP pressure change when purge operation started
Less than 0.1 kPa-g (0.75 mmHg-g)
2. EVAP pressure change during purge operation when vent valve closed
Less than 0.15 kPa-g (1.12 mmHg-g)

MONITOR RESULT

Refer to Checking Monitor Status (Click here).

CONFIRMATION DRIVING PATTERN

  1. Connect the Techstream to the DLC3.
  2. Turn the ignition switch to ON and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC operation).
  4. Turn the ignition switch off and wait for at least 30 seconds.
  5. Turn the ignition switch to ON and turn the Techstream on.
  6. Start the engine and wait 15 minutes or more.
  7. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes [C].
  8. Read the pending DTCs.

    HINT:
    1. If a pending DTC is output, the system is malfunctioning.
    2. If a pending DTC is not output, perform the following procedure.

  9. Enter the following menus: Powertrain / Engine and ECT / Utility / All readiness.
  10. Input the DTC: P0441.
  11. Check the DTC judgment result.

    Techstream Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    NOTICE:
    1. The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the Techstream. It takes a maximum of approximately 18 minutes.
    2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
    3. Do not run the engine during this operation.
    4. When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).

  12. Turn the ignition switch to ON and turn the Techstream on.
  13. Clear the DTCs (even if no DTCs are stored, perform the clear DTC operation).
  14. Turn the ignition switch off and wait for at least 30 seconds.
  15. Turn the ignition switch to ON.
  16. Turn the Techstream on [D].
  17. Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.
  18. After Evaporative System Check is completed, check All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  19. Input the DTC: P0441.
  20. Check the DTC judgment result [E].

    Techstream Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit

    HINT:
    If the judgment result shows ABNORMAL, the system has a malfunction.

  21. If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (Click here).

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.