DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0102 | MAF meter voltage less than 0.2 V for 3 seconds (1 trip detection logic: Engine speed less than 4000 rpm) (2 trip detection logic: Engine speed 4000 rpm or more) |
|
| P0103 | MAF meter voltage more than 4.9 V for 3 seconds (1 trip detection logic: Engine speed less than 4000 rpm) (2 trip detection logic: Engine speed 4000 rpm or more) |
|
| Mass Air Flow Rate (gm/sec.) | Malfunction |
| Approximately 0.0 |
|
| 160.0 or more | Open in E2G circuit |
| Related DTCs | P0102: MAF meter range check (Low voltage) P0103: MAF meter range check (High voltage) |
| Required Sensors/Components (Main) | MAF meter |
| Required Sensors/Components (Related) | Crankshaft position sensor |
| Frequency of Operation | Continuous |
| Duration | 3 seconds |
| MIL Operation | Immediate: Engine speed less than 4000 rpm 2 driving cycles: Engine speed 4000 rpm or more |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not stored | None |
| MAF meter voltage | Less than 0.2 V |
| MAF meter voltage | More than 4.9 V |
| MAF meter voltage | 0.4 V to 2.2 V |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.READ DTC OUTPUT |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
| Result | Proceed to |
| P0102 is output | A |
| P0103 is output | B |
|
| ||||
| A | |
| 2.CHECK MASS AIR FLOW METER (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the D7 MAF meter connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D7-1 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the D7 MAF meter connector.
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-3 (VG) - D74-74 (VG) | Always | Below 1 Ω |
| D7-2 (E2G) - D74-75 (E2G) | Always | Below 1 Ω |
| D7-3 (VG) or D74-74 (VG) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.INSPECT MASS AIR FLOW METER |
Inspect the mass air flow meter, referring to the On-vehicle Inspection for Mass Air Flow Meter (Click here).
Inspect the mass air flow meter, referring to the Inspection for Mass Air Flow Meter (Click here).
Inspect the function of the mass air flow meter.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / MAF.
Start the engine.
Check that the mass air flow meter value changes when the engine is raced.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (SENSOR GROUND) |
![]() |
Disconnect the D7 MAF meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-2 (E2G) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the D7 MAF meter connector.
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-2 (E2G) - D74-75 (E2G) | Always | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 7.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - INTEGRATION RELAY) |
Check the EFI NO. 2 fuse.
Remove the EFI NO. 2 fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| EFI NO. 2 fuse | Always | Below 1 Ω |
Reinstall the EFI NO. 2 fuse.
Disconnect the D7 MAF meter connector.
Remove the integration relay from the engine room relay block .
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D7-1 (+B) - 1B-4 | Always | Below 1 Ω |
| D7-1 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||