DTC P0976 Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2) |
DTC P0977 Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0976 | ECM detects short in solenoid valve S2 circuit 2 times when solenoid valve S2 is operated (1 trip detection logic) |
|
| P0977 | ECM detects open in solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated (1 trip detection logic) |
|
| Related DTCs | P0976: Shift solenoid valve S2/Range check (Low resistance) P0977: Shift solenoid valve S2/Range check (High resistance) |
| Required sensors/Components | Shift solenoid valve S2 |
| Frequency of operation | Continuous |
| Duration | 0.128 seconds or more |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Shift solenoid valve S2 | ON |
| Shift solenoid valve S2 | OFF |
| Shift solenoid valve S2 resistance | 8 Ω or less |
| Shift solenoid valve S2 resistance | 100 kΩ or more |
| Shift solenoid valve S2 resistance | 11 to 15 Ω at 20°C (68°F) |

| ECM gear shift command | 1st | 2nd | 3rd | 4th | 5th | 6th |
| Shift solenoid valve S2 | ON | ON | OFF | OFF | OFF | ON |
| 1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2) |
![]() |
Disconnect the D63 No. 1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 15 (S2) - Body ground | 20°C (68°F) | 11 to 15 Ω |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the D74 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D74-6 (S2) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Result | Proceed to |
| NG | A |
| OK (for 3UR-FE) | B |
| OK (for 3UR-FBE) | C |
|
| ||||
|
| ||||
| A | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE S2 |
![]() |
Remove shift solenoid valve S2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body | 20°C (68°F) | 11 to 15 Ω |
Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.
|
| ||||
| OK | ||
| ||