Home › STEERING › STEERING COLUMN › POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM

POWER TILT AND POWER TELESCOPIC STEERING COLUMN SYSTEM > DATA LIST / ACTIVE TEST

for Preparation Click here



READ DATA LIST

HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensor, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch ON.

  3. Turn the Techstream on.

  4. Enter the following menus: Body / Tilt & Telescopic / Data List.

  5. Check the values by referring to the table below.

    Tilt & Telescopic 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Tilt Position
    Current tilt position data / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Position
    Current telescopic position data / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Return Position
    Memorized tilt return position data / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Return Position
    Memorized telescopic return position data / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Memory Pos 1
    Tilt data of memory position 1 / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Memory Pos 1
    Telescopic data of memory position 1 / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Memory Pos 2
    Tilt data of memory position 2 / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Memory Pos 2
    Telescopic data of memory position 2 / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Up Limit
    Uppermost tilt position / Not Mem or Mem
    Not Mem: Position is not memorized
    Mem: Position is memorized
    -
    Tilt Up Limit Position
    Uppermost tilt position data / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Down Limit
    Lowermost tilt position / Not Mem or Mem
    Not Mem: Position is not memorized
    Mem: Position is memorized
    -
    Tilt Down Limit Position
    Lowermost tilt position data / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Short Limit
    Shortest telescopic position / Not Mem or Mem
    Not Mem: Position is not memorized
    Mem: Position is memorized
    -
    Telesco Short Limit Pos
    Shortest telescopic position data / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Long Limit
    Longest telescopic position / Not Mem or Mem
    Not Mem: Position is not memorized
    Mem: Position is memorized
    -
    Telesco Long Limit Pos
    Longest telescopic position data / min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Up Switch
    Input state of tilt up by manual switch / ON or OFF
    ON: Tilt up is activated by manual switch
    OFF: Tilt up is not activated by manual switch
    -
    Tilt Up SW(CAN)
    Communication state of tilt up input by manual switch / ON or OFF
    ON: Tilt up is activated by manual switch
    OFF: Tilt up is not activated by manual switch
    -
    Tilt Down Switch
    Input state of tilt down by manual switch / ON or OFF
    ON: Tilt down is activated by manual switch
    OFF: Tilt down is not activated by manual switch
    -
    Tilt Down SW(CAN)
    Communication state of tilt down input by manual switch / ON or OFF
    ON: Tilt down is activated by manual switch
    OFF: Tilt down is not activated by manual switch
    -
    Telesco Short Switch
    Input state of telescopic short by manual switch / ON or OFF
    ON: Telescopic short is activated by manual switch
    OFF: Telescopic short is not activated by manual switch
    -
    Telesco Short SW(CAN)
    Communication state of telescopic short input by manual switch / ON or OFF
    ON: Telescopic short is activated by manual switch
    OFF: Telescopic short is not activated by manual switch
    -
    Telesco Long Switch
    Input state of telescopic long by manual switch / ON or OFF
    ON: Telescopic long is activated by manual switch
    OFF: Telescopic long is not activated by manual switch
    -
    Telesco Long SW(CAN)
    Communication state of telescopic long input by manual switch / ON or OFF
    ON: Telescopic long is activated by manual switch
    OFF: Telescopic long is not activated by manual switch
    -
    T&T Manual SW Data
    Voltage data of manual switch / min.: 0.00 V, max.: 4.99 V
    Neutral position: Below 0.2 V
    Tilt up: 1.67 to 2.13 V
    Tilt down: 0.54 to 0.74 V
    Telescopic contract: 1.08 to 1.40 V
    Telescopic extend: 2.22 to 2.77 V
    -
    S/B Mem1
    Tilt and telescopic memory position 1 / Not Mem or Mem
    Not Mem: Position is not memorized
    Mem: Position is memorized
    -
    S/B Mem2
    Tilt and telescopic memory position 2 / Not Mem or Mem
    Not Mem: Position is not memorized
    Mem: Position is memorized
    -
    S/B Mem3
    Tilt and telescopic memory position 3 / Not Mem or Mem
    Not Mem: Position is not memorized
    Mem: Position is memorized
    -
    T&T Autoaway Function
    Auto away/return function / ON or OFF
    ON: Auto away/return function is allowed
    OFF: Auto away/return function is prohibited
    -
    Power Source Voltage
    Voltage data of power supply / min.: 0.00 V, max.: 19.99 V
    Actual power supply voltage
    11 to 14 V
    -
    Freeze Speed Info
    Vehicle speed data / min: 0 km/h (0 mph), max.: 255 km/h (158 mph)
    Actual vehicle speed
    -
    IG Switch (CAN)
    Communication state of ignition switch / ON or OFF
    ON: Communication is normal
    OFF: Communication is interrupted
    -
    IG Switch
    Input state of ignition switch / ON or OFF
    ON: Input signal is normal
    OFF: Input signal is interrupted
    -
    Key Switch(CAN)
    Communication state of unlock warning switch signal / ON or OFF
    ON: Communication is normal
    OFF: Communication is interrupted
    -
    Key Switch
    Input state of unlock warning switch / ON or OFF
    ON: Communication is normal
    OFF: Communication is interrupted
    -
    Key Code Confirm(CAN)
    Communication state of key code confirmation signal / ON or OFF
    ON: Communication is normal
    OFF: Communication is interrupted
    -
    Receive from Meter
    Communication state of combination meter signal / OK or Interpt
    OK: Communication is normal
    Interpt: Communication is interrupted
    -
    Receive from Seat ECU
    Communication state of front power seat control ECU and switch LH signal / OK or Interpt
    OK: Communication is normal
    Interpt: Communication is interrupted
    -
    Receive from Combi
    Communication state of combination switch ECU signal / OK or Interpt
    OK: Communication is normal
    Interpt: Communication is interrupted
    -
    J/B
    Communication state of main body ECU signal / OK or Interpt
    OK: Communication is normal
    Interpt: Communication is interrupted
    -
    B/B
    Communication state of optional after parts ECU signal / OK or Interpt
    OK: Communication is normal
    Interpt: Communication is interrupted
    -
    The Number of DTCs
    Number of diagnostic trouble codes / min.: 0, max.: 255
    Actual number of diagnostic trouble codes
    -


PERFORM ACTIVE TEST

HINT:
Using the Techstream to perform Active Tests allows relays, VSVs and actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch ON.

  3. Turn the Techstream on.

  4. Enter the following menus: Body / Tilt & Telescopic / Active Test.

  5. Check the values by referring to the table below.

    Tilt & Telescopic 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Tilt operation
    Tilt operation
    Up / Down
    -
    Telesco operation
    Telescopic operation
    Long / Short
    -