Home › BODY › MIRROR › OUTER MIRROR SWITCH

OUTER MIRROR SWITCH > INSPECTION

for Preparation Click here



1. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/o Retract Mirror)


B167984E02
  1. Check the resistance.

    1. Select "L" on the left/right adjustment switch.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      4 (MLV) - 8 (B)
      6 (M+) - 7 (E)
      UP
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      4 (MLV) - 7 (E)
      6 (M+) - 8 (B)
      DOWN
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      5 (MLH) - 8 (B)
      6 (M+) - 7 (E)
      LEFT
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      5 (MLH) - 7 (E)
      6 (M+) - 8 (B)
      RIGHT
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher

      If the result is not as specified, replace the outer mirror switch.

    3. Select "R" on the left/right adjustment switch.

    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      3 (MRV) - 8 (B)
      6 (M+) - 7 (E)
      UP
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      3 (MRV) - 7 (E)
      6 (M+) - 8 (B)
      DOWN
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      2 (MRH) - 8 (B)
      6 (M+) - 7 (E)
      LEFT
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      2 (MRH) - 7 (E)
      6 (M+) - 8 (B)
      RIGHT
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher

      If the result is not as specified, replace the outer mirror switch.



2. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/ Retract Mirror)


B167985E02
  1. Inspect the outer mirror switch.

    1. Select "L" on the left/right adjustment switch.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      4 (MLV) - 8 (B)
      6 (M+) - 7 (E)
      UP
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      4 (MLV) - 7 (E)
      6 (M+) - 8 (B)
      DOWN
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      5 (MLH) - 8 (B)
      6 (M+) - 7 (E)
      LEFT
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      5 (MLH) - 7 (E)
      6 (M+) - 8 (B)
      RIGHT
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher

      If the result is not as specified, replace the outer mirror switch.

    3. Select "R" on the left/right adjustment switch.

    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      3 (MRV) - 8 (B)
      6 (M+) - 7 (E)
      UP
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      3 (MRV) - 7 (E)
      6 (M+) - 8 (B)
      DOWN
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      2 (MRH) - 8 (B)
      6 (M+) - 7 (E)
      LEFT
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      2 (MRH) - 7 (E)
      6 (M+) - 8 (B)
      RIGHT
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher

      If the result is not as specified, replace the outer mirror switch.

  1. Inspect the retract switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      8 (B) - 9 (MR)
      10 (MF) - 7(E)
      Pressed
      (Retracts)
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      8 (B) - 10 (MF)
      7 (E) - 9 (MR)
      Pressed
      (Driving position)
      Below 1 Ω
      Not pressed
      10 kΩ or higher

      If the result is not as specified, replace the outer mirror switch.



3. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/ Memory)


B167772E04
  1. Inspect the outer mirror switch.

    1. Select "L" on the left/right adjustment switch.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      3 (M+) - 2 (E)
      UP
      Pressed
      100 Ω
      Not pressed
      10 kΩ or higher
      3 (M+) - 2 (E)
      DOWN
      Pressed
      470 Ω
      Not pressed
      10 kΩ or higher
      3 (M+) - 2 (E)
      LEFT
      Pressed
      800 Ω
      Not pressed
      10 kΩ or higher
      3 (M+) - 2 (E)
      RIGHT
      Pressed
      250 Ω
      Not pressed
      10 kΩ or higher
      1 (MSE) - 2 (E)
      L switch
      Pressed
      100 Ω
      Not pressed
      10 kΩ or higher

      If the result is not as specified, replace the outer mirror switch.

    3. Select "R" on the left/right adjustment switch.

    4. Using an ohmmeter, measure the resistance and check the results in accordance with the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      3 (M+) - 2 (E)
      UP
      Pressed
      100 Ω
      Not pressed
      10 kΩ or higher
      3 (M+) - 2 (E)
      DOWN
      Pressed
      470 Ω
      Not pressed
      10 kΩ or higher
      3 (M+) - 2 (E)
      LEFT
      Pressed
      800 Ω
      Not pressed
      10 kΩ or higher
      3 (M+) - 2 (E)
      RIGHT
      Pressed
      250 Ω
      Not pressed
      10 kΩ or higher
      1 (MSE) - 2 (E)
      R switch
      Pressed
      Below 1 Ω
      Not pressed
      10 kΩ or higher

      If the result is not as specified, replace the outer mirror switch.

  1. Inspect the retract switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      6 (B) - 7 (MR)
      8 (MF) - 4 (E2)
      Pressed
      (Retracts)
      Below 1 Ω
      Not pressed
      10 kΩ or higher
      6 (B) - 8 (MF)
      4 (E2) - 7 (MR)
      Pressed
      (Driving position)
      Below 1 Ω
      Not pressed
      10 kΩ or higher

      If the result is not as specified, replace the outer mirror switch.