Home › BODY › WINDSHIELD / WINDOWGLASS › POWER WINDOW CONTROL SYSTEM (w/o Jam Protection Function)

POWER WINDOW CONTROL SYSTEM (w/o Jam Protection Function) > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST

HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch ON.

  3. Turn the Techstream on.

  4. Enter the following menus: Body Electrical / Main Body / Data List.

  5. According to the display on the Techstream, read the Data List.

    Main Body: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    D Door Courtesy SW
    Driver side door courtesy switch signal / ON or OFF
    ON: Driver door open
    OFF: Driver door closed
    -
    P Door Courtesy SW
    Front passenger side door courtesy switch signal / ON or OFF
    ON: Front passenger door open
    OFF: Front passenger door closed
    -


ACTIVE TEST

HINT:
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch ON.

  3. Turn the Techstream on.

  4. Enter the following menus: Body Electrical / Main Body / Active Test.

  5. According to the display on the Techstream, perform the Active Test.

    Main Body: 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    IG OFF P/W Control Permission Output
    Power window control permission output
    ON or OFF
    -