PURGE VALVE > INSPECTION |
| 1. INSPECT PURGE VSV |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 23 to 26 Ω |
| 1 - VSV body ground | Always | 10 MΩ or higher |
| 2 - VSV body ground | 10 MΩ or higher |
![]() |
Inspect the purge VSV operation.
Check that air does not flow from ports.
![]() |
Apply battery voltage across the terminals.
Check that air flows from ports.
If the result is not as specified, replace the purge VSV.