DTC Code
| Monitoring Item
| Malfunction Detection Condition
| Trouble Area
| Detection Timing
| Detection Logic
|
P043E
| Reference orifice clogged
| P043E, P043F, P2401, P2402 and P2419 present when one of following conditions met during key-off EVAP monitor:
- Reference orifice clogged
- Reference orifice high-flow
- Leak detection pump OFF malfunction
- Leak detection pump ON malfunction
- Vent valve ON (close) malfunction
| - Canister pump module (Reference orifice, leak detection pump, vent valve)
- Connector/wire harness (Canister pump module - ECM)
- EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)
- ECM
| While ignition switch off
| 2 trip
|
P043F
| Reference orifice high-flow
|
P2401
| Leak detection pump stuck OFF
|
P2402
| Leak detection pump stuck ON
|
P2419
| Vent valve stuck closed
|
Sequence
| Operation
| Description
| Duration
|
-
| ECM activation
| Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off.
| -
|
A
| Atmospheric pressure measurement
| Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa-a and 110 kPa-a (525 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
| 60 seconds
|
B
| First reference pressure measurement
| In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
| 60 seconds
|
C
| EVAP system pressure measurement
| Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
| 15 minutes*
|
D
| Purge VSV monitor
| Purge VSV opened and then EVAP system pressure measured by ECM. Large increase indicates normality.
| 10 seconds
|
E
| Second reference pressure measurement
| After second reference pressure measurement, leak check performed by comparing first and second reference pressure. If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
| 60 seconds
|
-
| Final check
| Atmospheric pressure measured and then monitoring result recorded by ECM.
| -
|
Monitor runs whenever following DTCs not present
| P0452, P0453 (EVAP System)
|
EVAP key-off monitor runs when all of following conditions met
| -
|
Atmospheric pressure
| 70 to 111 kPa (525 to 833 mmHg)
|
Battery voltage
| 10.5 V or more
|
Vehicle speed
| Below 4 km/h (2.5 mph)
|
Ignition switch
| Off
|
Time after key off
| 5 or 7 or 9.5 hours
|
Purge VSV
| Not operated by scan tool
|
Vent valve
| Not operated by scan tool
|
Leak detection pump
| Not operated by scan tool
|
Both of following conditions met before key off
| Conditions 1 and 2
|
1. Duration that vehicle driven
| 5 minutes or more
|
2. EVAP purge operation
| Performed
|
ECT
| 4.4 to 35°C (40 to 95°F)
|
IAT
| 4.4 to 35°C (40 to 95°F)
|