Home › ENGINE ยท 1GR-FE › EXHAUST › EXHAUST PIPE (except Regular Cab Standard Deck)

EXHAUST PIPE (except Regular Cab Standard Deck) > INSTALLATION

for Preparation Click here



1. INSTALL FRONT EXHAUST PIPE ASSEMBLY
  1. Install a new gasket and the front exhaust pipe to the exhaust manifold RH with 3 new nuts.

    Torque:
    54 N*m{ 554 kgf*cm , 40 ft.*lbf }



2. INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY
  1. Install the front No. 2 exhaust pipe to the exhaust pipe support.

  1. Install a new gasket and the front No. 2 exhaust pipe to the exhaust manifold LH with 3 new nuts.

    Torque:
    54 N*m{ 554 kgf*cm , 40 ft.*lbf }



3. INSTALL CENTER EXHAUST PIPE ASSEMBLY
  1. Install the center exhaust pipe to the 3 exhaust pipe supports.

  1. Install 2 new gaskets to the front exhaust pipe LH and RH.

  1. Install the center exhaust pipe with the 4 bolts.

    Torque:
    48 N*m{ 489 kgf*cm , 35 ft.*lbf }



4. INSTALL TAILPIPE ASSEMBLY
  1. Install the tailpipe to the exhaust pipe support.



    A236957E02
  1. Set a new gasket to the center exhaust pipe.

  1. Connect the tailpipe to the center pipe with a new clamp.

    Torque:
    32 N*m{ 326 kgf*cm , 24 ft.*lbf }

    Text in Illustration 
    *a
    Upper
    *b
    LH Side
    *c
    Front

    HINT:
    Install the clamp within the angle range shown in the illustration.



5. INSTALL AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)


    A240681E01
  1. Using SST, install the sensor.

    SST
    09224-00010  

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    Text in Illustration 
    *a
    Fulcrum Length

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.
    3. Perform "Inspection After Repairs" after replacing the air fuel ratio sensor (Click here).

  1. Connect the connector.



6. INSTALL AIR FUEL RATIO SENSOR (for Bank 2 Sensor 1)


    A240679E01
  1. Using SST, install the sensor.

    SST
    09224-00010  

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    Text in Illustration 
    *a
    Fulcrum Length

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.
    3. Perform "Inspection After Repairs" after replacing the air fuel ratio sensor (Click here).

  1. Connect the connector.



7. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)


    A240675E01
  1. Using SST, install the sensor.

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    Text in Illustration 
    *a
    Fulcrum Length

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.
    3. Perform "Inspection After Repairs" after replacing the Perform "Inspection After Repairs" after replacing the heated oxygen sensor (Click here).

  1. Connect the connector and 2 clamps.



8. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)


    A240677E01
  1. Using SST, install the sensor.

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    Text in Illustration 
    *a
    Fulcrum Length

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.
    3. Perform "Inspection After Repairs" after replacing the Perform "Inspection After Repairs" after replacing the heated oxygen sensor (Click here).

  1. Connect the connector.



9. INSPECT FOR EXHAUST GAS LEAK
  1. If gas is leaking, tighten the areas necessary to stop the leak. Replace damaged parts as necessary.