LIGHTING SYSTEM > Hazard Warning Switch Circuit |

| 1.INSPECT HAZARD WARNING SIGNAL SWITCH |
![]() |
Remove the hazard warning signal switch (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 - 4 | Hazard warning switch ON | Below 1 Ω |
| Hazard warning switch OFF | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH - TURN SIGNAL FLASHER AND BODY GROUND) |
![]() |
Disconnect the L3 switch connector.
Disconnect the J29 relay connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L3-4 - J29-12 (HAZ) | Always | Below 1 Ω |
| L3-1 - Body ground | ||
| L3-4 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||