SHIFT LEVER ASSEMBLY (for Floor Shift Type) > INSPECTION |
| 1. INSPECT TRANSMISSION CONTROL SWITCH |
![]() |
Disconnect the transmission control switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 (IG) - 7 (S) | Shift lever in S, "+" or "- " | Below 1 Ω |
| 2 (SFTU) - 5 (E) | Shift lever held in "+" (Up-shift) | |
| 1 (SFTD) - 5 (E) | Shift lever held in "-" (Down-shift) | |
| 3 (IG) - 7 (S) | Shift lever not in S, "+" or "-" | 10 kΩ or higher |
| 2 (SFTU) - 5 (E) | Shift lever in S | |
| 1 (SFTD) - 5 (E) |