Home › ENGINE ยท 1GR-FE › EMISSION CONTROL › AIR SWITCHING VALVE (for Bank 1)

AIR SWITCHING VALVE (for Bank 1) > REMOVAL

for Preparation Click here



1. REMOVE AIR CLEANER CAP AND HOSE


    A239075
  1. Remove the air cleaner cap and hose.

    1. Disconnect the mass air flow meter connector, vacuum hose and ventilation hose and detach the 4 clamps.

    2. Loosen the clamp.

    3. Detach the 4 hook clamps, and then remove the air cleaner cap and hose.



2. REMOVE AIR CLEANER CASE SUB-ASSEMBLY
  1. Remove the air cleaner filter element.



    A239077
  1. Remove the 2 bolts and air cleaner case.



3. REMOVE AIR TUBE


    A239078
  1. Remove the 2 bolts, 2 nuts and air tube.

  1. Remove the 2 gaskets from the air tube.

    NOTICE:
    Be careful not to damage the installation surface of the gaskets.



4. REMOVE EMISSION CONTROL VALVE SET


    A239079
  1. Disconnect the emission control valve set connector.

  1. Disconnect the air hose from the emission control valve set.



    A239080
  1. Remove the 3 nuts and emission control valve set.