AIR SWITCHING VALVE (for Bank 2) > REMOVAL |
| 1. REMOVE V-BANK COVER SUB-ASSEMBLY |
![]() |
Raise the front of the V-bank cover to detach the 2 pins. Then remove the 2 V-bank cover hooks from the bracket, and remove the V-bank cover.
| 2. REMOVE AIR CLEANER HOSE ASSEMBLY |
![]() |
Disconnect the vacuum sensing hose and ventilation hose.
Loosen the 2 clamps.
Remove the air cleaner hose.
| 3. DISCONNECT NO. 3 VENTILATION HOSE |
![]() |
Disconnect the No. 3 ventilation hose.
| 4. DISCONNECT NO. 1 AIR HOSE |
![]() |
Disconnect the No. 1 air hose.
| 5. REMOVE AIR SWITCHING VALVE ASSEMBLY |
![]() |
Disconnect the connector and clamp.
Remove the bolt and disconnect the wire harness clamp bracket.
![]() |
Remove the 2 bolts.
![]() |
Remove the 3 bolts, air switching valve and gasket.