DTC P0010 Camshaft Position "A" Actuator Circuit (Bank 1) |
DTC P0020 Camshaft Position "A" Actuator Circuit (Bank 2) |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0010 | Open or short in the camshaft timing oil control valve (for intake side of bank 1) circuit (1 trip detection logic). |
|
| P0020 | Open or short in the camshaft timing oil control valve (for intake side of bank 2) circuit (1 trip detection logic). |
|
| Related DTCs | P0010: Camshaft timing oil control valve range check (bank 1) P0020: Camshaft timing oil control valve range check (bank 2) |
| Required Sensors/Components (Main) | Camshaft timing oil control valve assembly |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 1 second |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| All of following conditions met | - |
| Starter | OFF |
| Ignition switch | ON |
| Time after ignition switch off to ON | 0.5 seconds or more |
| One of following conditions met | - |
| A. All of following conditions met | - |
| Battery voltage | 11 V or more, and less than 13 V |
| Target duty cycle | Less than 70% |
| B. All of following conditions met | - |
| Battery voltage | 13 V or more |
| Target duty cycle | Less than 80% |
| Current cut status | Not cut |
| Output duty cycle | 100% or more |
| Output duty cycle | 3% or less |
| Camshaft timing oil control valve duty ratio | 3 to 100% |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|

| 1.CHECK DTC (DTC P0010 OR P0020) |
Clear the DTCs after recording the freeze frame data and DTCs.
Turn the ignition switch off.
Allow the engine to idle and check for DTCs.
Check that P0010 or P0020 is output.
|
| ||||
| OK | |
| 2.INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY (FOR INTAKE SIDE) |
Inspect the camshaft timing oil control valve assembly (for intake side) (Click here).
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY - ECM) |
Disconnect the camshaft timing oil control valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D42-1 - D74-58 (OC1+) | Always | Below 1 Ω |
| D43-1 - D74-52 (OC2+) | Always | Below 1 Ω |
| D42-2 - D74-57 (OC1-) | Always | Below 1 Ω |
| D43-2 - D74-51 (OC2-) | Always | Below 1 Ω |
| D42-1 or D74-58 (OC1+) - Body ground | Always | 10 kΩ or higher |
| D43-1 or D74-52 (OC2+) - Body ground | Always | 10 kΩ or higher |
| D42-2 or D74-57 (OC1-) - Body ground | Always | 10 kΩ or higher |
| D43-2 or D74-51 (OC2-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||