Home › ENGINE ยท 3UR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P2610    ECM / PCM Internal Engine Off Timer Performance

for Preparation Click here


DTC SUMMARY


DTC Code
Monitoring Item
Malfunction Detection Condition
Trouble Area
Detection Timing
Detection Logic
P2610
Soak timer (built into ECM)
ECM internal malfunction
ECM
Engine running
2 trip

DESCRIPTION

To ensure the accuracy of the EVAP (Evaporative Emission) monitor values, the soak timer, which is built into the ECM, measures 5 hours (+/-15 minutes) from when the ignition switch is turned off, before the monitor is run. This allows the fuel to cool down, which stabilizes the EVAP pressure. When 5 hours have elapsed, the ECM turns on.

A164737E01


MONITOR DESCRIPTION

  1. While the engine is running, the ECM monitors the synchronization of the soak timer and the CPU clock. If these two are not synchronized, the ECM interprets this as a malfunction, illuminates the MIL and stores the DTC.
  2. If the soak timer activates the ECM even though only a short amount of time has elapsed since the ignition switch was turned off, or if the soak timer does not activate the ECM even though a considerable amount of time has elapsed since the ignition switch was turned off, the ECM determines that the soak timer is malfunctioning, illuminates the MIL and stores a DTC the next time the ignition switch is turned ON.

MONITOR STRATEGY


Required Sensors/Components
ECM
Frequency of Operation
Once per driving cycle
Duration
2 times: Case 1
-: Case 2 and 3
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


All 
Monitor runs whenever following DTCs are not stored
None

Case 1 
All of the following conditions are met
-
Battery voltage
8 V or more
Ignition switch
OFF
CPU clock elapsed time
1.96608 seconds or more

Case 2 
All of the following conditions are met
-
Internal engine off timer (elapsed time from engine stop)
10 minutes or more, and less than 30 minutes
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

Case 3 
All of the following conditions are met
-
Internal engine off timer (elapsed time from engine stop)
10 minutes or more, and less than 30 minutes
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS


Case 1 
One of the following conditions is met
Condition A, B or C
A. Both of the following conditions are met
Condition (a) and (b)
(a) CPU clock elapsed time
1.96608 seconds or more, and less than 8.323072 seconds
(b) Internal Engine off timer
9.375 seconds or more
B. Both of the following conditions are met
Condition (c) and (d)
(c) CPU clock elapsed time
8.323072 to 10.420224 seconds
(d) Internal Engine off timer
18.75 seconds or more
C. Both of the following conditions are met
Condition (e) and (f)
(e) CPU clock elapsed time
More than 10.420224 seconds
(f) Internal Engine off timer
Less than 9.375 seconds

Case 2 
ECM had the started record
Yes

Case 3 
ECM had the started record
No

CONFIRMATION DRIVING PATTERN


A199319E01

  1. Connect the Techstream to the DLC3.
  2. Turn the ignition switch to ON and turn the Techstream on.
  3. Clear DTCs (even if no DTCs are stored, perform the clear DTC operation).
  4. Turn the ignition switch off and wait for at least 30 seconds.
  5. Turn the ignition switch to ON and turn the Techstream on [A].
  6. Start the engine.
  7. Idle the engine for 10 minutes or more.
  8. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes [B].
  9. Read the Pending DTCs.

    HINT:
    1. If a pending DTC is output, the system is malfunctioning.
    2. If a pending DTC is not output, perform the following procedure.

  10. Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
  11. Input the DTC: P2610.
  12. Check the DTC judgment result.

    Tester Display
    Description
    NORMAL
    1. DTC judgment completed
    2. System normal
    ABNORMAL
    1. DTC judgment completed
    2. System abnormal
    INCOMPLETE
    1. DTC judgment not completed
    2. Perform driving pattern after confirming DTC enabling conditions
    N/A
    1. Unable to perform DTC judgment
    2. Number of DTCs which do not fulfill DTC preconditions has reached ECU's memory limit

    HINT:
    If the judgment result shows ABNORMAL, the system has a malfunction.

  13. If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (Click here).

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.


INSPECTION PROCEDURE

HINT:
  1. DTC P2610 is set if an internal ECM problem is detected. Diagnostic procedures are not required. ECM replacement is necessary.
  2. Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.REPLACE ECM
  1. Replace the ECM (Click here).


NEXT


2.CHECK WHETHER DTC OUTPUT RECURS
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Clear DTCs (Click here).

  1. Start the engine and wait for 10 minutes or more.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes / Pending.

  1. If no pending DTC is displayed, the repair has been successfully completed.


NEXT

END