Home › TRANSMISSION · A750E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0705    Transmission Range Sensor Circuit Malfunction (PRNDL Input)

for Preparation Click here


DESCRIPTION

The Park/Neutral Position (PNP) switch detects the shift lever position and sends signals to the ECM.

DTC Code
DTC Detection Condition
Trouble Area
P0705
When one of following conditions is met:
(A) Any 2 or more of the following signals are ON simultaneously (2 trip detection logic)
  1. One of the following conditions is met
    1. P input signal is ON
    1. N input signal is ON
    1. NSW input signal is ON
  2. R input signal is ON
  3. D input signal is ON
(B) When any of following conditions is met for 2.0 sec. or more in the S position (2 trip detection logic)
  1. P input signal is ON
  2. N input signal is ON
  3. NSW input signal is ON
  4. R input signal is ON
(C) All switches are OFF simultaneously for P, R, N, D and NSW (2 trip detection logic)
  1. Open or short in park/neutral position switch circuit
  2. Transmission control switch
  3. Park/neutral position switch
  4. ECM

MONITOR DESCRIPTION

These DTCs indicate a problem with the park/neutral position switch and the wire harness in the park/neutral position switch circuit.
The park/neutral position switch detects the shift lever position and sends a signal to the ECM.
For security, the park/neutral position switch detects the shift lever position so that the engine can be started only when the shift lever is on P or N.
The park/neutral position switch sends a signal to the ECM according to the shift lever position (P, R, N, D or S).
The ECM determines that there is a problem with the switch or related parts if it receives more than 1 position signal simultaneously. The ECM will illuminate the MIL and store the DTC.

MONITOR STRATEGY


Related DTCs
P0705: Park/neutral position switch/Verify switch input
Required sensors/Components
Park/neutral position switch
Frequency of operation
Continuous
Duration
Condition (A) and (B)
2 sec.
Condition (C)
60 sec.
MIL operation
2 driving cycles
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


All 
The monitor will run whenever the following DTCs are not present
None
Battery voltage
8 V or more
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS

  1. One of the following conditions is met: Condition (A), (B) or (C)
  2. Condition (A)
    1. When 2 or more of the following signals are input at the same time

      One of the following conditions is met
      1. P switch
      2. N switch
      3. NSW switch
      ON
      R switch
      ON
      D switch
      ON
    Condition (B)
    1. When the shift lever is in the S position, one of the following conditions is met

      P switch
      ON
      N switch
      ON
      NSW switch
      ON
      R switch
      ON
    Condition (C)
    1. All of the following conditions are met

      P switch
      OFF
      N switch
      OFF
      NSW switch
      OFF
      R switch
      OFF
      D switch
      OFF

COMPONENT OPERATING RANGE


Park/neutral position switch
The park/neutral position switch sends only one signal to the ECM

WIRING DIAGRAM


C162206E01


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).


DATA LIST

HINT:
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Warm up the engine.

  2. Turn the ignition switch off.

  3. Connect the Techstream to the DLC3.

  4. Turn the ignition switch to ON.

  5. Turn the Techstream on.

  6. Enter the following menus: Powertrain / Engine and ECT / Data List.

  7. According to the display on the Techstream, read the Data List.

    Engine and ECT: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Neutral Position SW Signal
    PNP switch status/
    ON or OFF
    Shift lever is:
    1. On P or N: ON
    2. Not on P or N: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    Shift SW Status (P Range)
    PNP switch status/
    ON or OFF
    Shift lever is:
    1. On P: ON
    2. Not on P: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    Shift SW Status (R Range)
    PNP switch status/
    ON or OFF
    Shift lever is:
    1. On R: ON
    2. Not on R: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    Shift SW Status (N Range)
    PNP switch status/
    ON or OFF
    Shift lever is:
    1. On N: ON
    2. Not on N: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    Sports Shift Up SW
    Sport shift up switch status/
    ON or OFF
    1. ON: Shift lever held in "+" (up-shift)
    2. OFF: Shift lever not in "+" (up-shift)
    -
    Sports Shift Down SW
    Sport shift down switch status/
    ON or OFF
    1. ON: Shift lever held in "-" (down-shift)
    2. OFF: Shift lever not in "-" (down-shift)
    -
    Sports Mode Selection SW
    Sport mode select switch status/
    ON or OFF
    Shift lever position is:
    1. ON: S, "+" or "-"
    2. OFF: Not on S, "+" or "-"
    -
    Shift SW Status (D Range)
    PNP switch status/
    ON or OFF
    Shift lever is:
    1. On D: ON
    2. Not on D: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect

1.INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY


    C160109E15
  1. Disconnect the D35 park/neutral position switch connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1. 2 (RB) - 6 (PL)
    2. 4 (B) - 5 (L)
    Shift lever position on P
    Below 1 Ω
    2 (RB) - 1 (RL)
    Shift lever position on R
    Below 1 Ω
    1. 2 (RB) - 9 (NL)
    2. 4 (B) - 5 (L)
    Shift lever position on N
    Below 1 Ω
    2 (RB) - 7 (DL)
    1. Shift lever position on D
    2. Shift lever position on S, "+" or "-"
    Below 1 Ω
    1. 2 (RB) - 6 (PL)
    2. 4 (B) - 5 (L)
    Shift lever position not on P
    10 kΩ or higher
    2 (RB) - 1 (RL)
    Shift lever position not on R
    10 kΩ or higher
    1. 2 (RB) - 9 (NL)
    2. 4 (B) - 5 (L)
    Shift lever position not on N
    10 kΩ or higher
    2 (RB) - 7 (DL)
    1. Shift lever position not on D
    2. Shift lever position not on S, "+" or "-"
    10 kΩ or higher



NG
REPLACE PARK/NEUTRAL POSITION SWITCH ASSEMBLY (Click here)
OK


2.INSPECT TRANSMISSION CONTROL SWITCH


    C159524E02
  1. for Column Shift Type:

    1. Disconnect the J25 transmission control switch connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      6 (IG) - 13 (S)
      Shift lever position on S, "+" or "-"
      Below 1 Ω
      6 (IG) - 13 (S)
      Shift lever position not on S, "+" or "-"
      10 kΩ or higher



    C146679E04
  1. for Floor Shift Type:

    1. Disconnect the J24 transmission control switch connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      3 (IG) - 7 (S)
      Shift lever position on S, "+" or "-"
      Below 1 Ω
      3 (IG) - 7 (S)
      Shift lever position not on S, "+" or "-"
      10 kΩ or higher

      Result 
      Result
      Proceed to
      OK
      A
      NG (for Column Shift Type)
      B
      NG (for Floor Shift Type)
      C



B
REPLACE COLUMN SHIFT SHIFT LEVER SUB-ASSEMBLY (TRANSMISSION CONTROL SWITCH) (Click here)

C
REPLACE TRANSMISSION FLOOR SHIFT ASSEMBLY (TRANSMISSION CONTROL SWITCH) (Click here)
A


3.CHECK PARK/NEUTRAL POSITION SWITCH ASSEMBLY (POWER SOURCE)


    C159064E17
  1. Disconnect the D35 park/neutral position switch connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D35-2 (RB) - Body ground
    Ignition switch ON
    11 to 14 V
    D35-2 (RB) - Body ground
    Ignition switch off
    Below 1 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (PARK/NEUTRAL POSITION SWITCH - IGNITION SWITCH)
OK


4.CHECK TRANSMISSION CONTROL SWITCH (POWER SOURCE)


    C159066E01
  1. for Column Shift Type:

    1. Disconnect the J25 transmission control switch connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard voltage:
      Tester Connection
      Switch Condition
      Specified Condition
      J25-6 (IG) - Body ground
      Ignition switch ON
      11 to 14 V
      J25-6 (IG) - Body ground
      Ignition switch off
      Below 1 V



    C146729E02
  1. for Floor Shift Type:

    1. Disconnect the J24 transmission control switch connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard voltage:
      Tester Connection
      Switch Condition
      Specified Condition
      J24-3 (IG) - Body ground
      Ignition switch ON
      11 to 14 V
      J24-3 (IG) - Body ground
      Ignition switch off
      Below 1 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION CONTROL SWITCH - IGNITION SWITCH)
OK


5.CHECK HARNESS AND CONNECTOR (PARK/NEUTRAL POSITION SWITCH - ECM)


    C159422E04
  1. Disconnect the D74 ECM connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    D74-2 (P) - Body ground
    1. Ignition switch ON
    2. Shift lever position on P
    11 to 14 V
    D74-26 (R) - Body ground
    1. Ignition switch ON
    2. Shift lever position on R
    11 to 14 V*
    D74-25 (N) - Body ground
    1. Ignition switch ON
    2. Shift lever position on N
    11 to 14 V
    D74-27 (D) - Body ground
    1. Ignition switch ON
    2. Shift lever position on D
    11 to 14 V
    D74-120 (NSW) - Body ground
    1. Ignition switch ON
    2. Shift lever position not on P or N
    11 to 14 V
    D74-2 (P) - Body ground
    1. Ignition switch ON
    2. Shift lever position not on P
    Below 1 V
    D74-26 (R) - Body ground
    1. Ignition switch ON
    2. Shift lever position not on R
    Below 1 V
    D74-25 (N) - Body ground
    1. Ignition switch ON
    2. Shift lever position not on N
    Below 1 V
    D74-27 (D) - Body ground
    1. Ignition switch ON
    2. Shift lever position not on D
    Below 1 V
    D74-120 (NSW) - Body ground
    1. Ignition switch ON
    2. Shift lever position on P or N
    Below 1 V

    HINT:
    *: The voltage will drop slightly due to the turning on of the back-up light.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - ECM)


    C159423E01
  1. Disconnect the A24 ECM connector.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    A24-25 (S) - Body ground
    Shift lever position on S, "+" or "-"
    11 to 14 V
    A24-25 (S) - Body ground
    Shift lever position not on S, "+" or "-"
    Below 1 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)