Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AMBIENT TEMPERATURE SENSOR

AMBIENT TEMPERATURE SENSOR > INSPECTION

for Preparation Click here



1. INSPECT COOLER (AMBIENT TEMPERATURE SENSOR) THERMISTOR


E106870E32
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
    1. When measuring the resistance, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    Text in Illustration 
    *1
    Sensor Area
    *a
    Component without harness connected
    (Cooler (Ambient Temperature Sensor) Thermistor)
    *b
    Resistance (kΩ)
    *c
    Temperature (°C (°F))
    If the result is not as specified, replace the cooler (ambient temperature sensor) thermistor.