Home › ENGINE · 1UR-FE › CHARGING › GENERATOR

GENERATOR > INSPECTION

for Preparation Click here



1. INSPECT GENERATOR ROTOR ASSEMBLY


    A117220
  1. Check the rotor for an open circuit.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      100 A Type Type 
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Slip ring
      20°C (68°F)
      2.3 to 2.7 Ω
      150 A Type 
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Slip ring
      20°C (68°F)
      1.5 to 1.9 Ω

      If the result is not as specified, replace the generator rotor assembly.



    A117221
  1. Check if the rotor is grounded.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Rotor
      Always
      10 kΩ or higher

      If the result is not as specified, replace the generator rotor assembly.

  1. Check that the slip rings are not rough or scored.
    If rough or scored, replace the generator rotor assembly.



    A117222E01
  1. Using a vernier caliper, measure the slip ring diameter.

    Standard diameter:
    14.2 to 14.4 mm (0.559 to 0.567 in.)

    Minimum diameter:
    14.0 mm (0.551 in.)

    If the diameter is less than the minimum, replace the generator rotor assembly.



2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY


A079305E02
  1. Using a vernier caliper, measure the exposed brush length.

    Standard exposed length:
    10.5 mm (0.413 in.)

    Minimum exposed length:
    4.5 mm (0.177 in.)

    If the exposed length is less than the minimum, replace the generator brush holder assembly.



3. INSPECT GENERATOR DRIVE END FRAME BEARING


    A156418
  1. When rotating the bearing, check that there is no abnormal noise and that it rotates smoothly.
    If necessary, replace the generator drive end frame bearing.



4. INSPECT GENERATOR ROTOR BEARING


    A163064
  1. When rotating the bearing, check that there is no abnormal noise and that it rotates smoothly.
    If necessary, replace the generator rotor assembly.