FRONT EVAPORATOR TEMPERATURE SENSOR > INSPECTION

for Preparation Click here



1. INSPECT NO. 1 COOLER THERMISTOR


    E126546E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    -5°C (23°F)
    5.65 to 6.95 kΩ
    0°C (32°F)
    4.40 to 5.35 kΩ
    5°C (41°F)
    3.40 to 4.15 kΩ
    10°C (50°F)
    2.70 to 3.25 kΩ
    15°C (59°F)
    2.14 to 2.58 kΩ
    20°C (68°F)
    1.71 to 2.05 kΩ
    25°C (77°F)
    1.38 to 1.64 kΩ
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    1. When measuring, the sensor temperature must be almost the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    Text in Illustration 
    *1
    Sensor
    *a
    Component without harness connected
    (No. 1 Cooler Thermistor)
    *b
    Resistance (kΩ)
    *c
    Temperature (°C (°F))
    If the result is not as specified, replace the sensor.