SOLAR SENSOR (for Automatic Air Conditioning System) > INSPECTION |
| 1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR (SOLAR SENSOR) |
![]() |
Connect the positive (+) lead from the battery to terminal 6 and the negative (-) lead to terminal 3, and then measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (TSL) - 3 (CLTE) | Sensor subjected to electric light | 0.8 to 4.3 V |
| Sensor covered with a cloth | 0.8 V or less | |
| 2 (TSR) - 3 (CLTE) | Sensor subjected to electric light | 0.8 to 4.3 V |
| Sensor covered with a cloth | 0.8 V or less |
| *a | Component without harness connected (Automatic Light Control Sensor (Solar Sensor)) |