Home › ENGINE ยท 1GR-FE › CHARGING › GENERATOR

GENERATOR > REMOVAL

for Preparation Click here



1. PRECAUTION

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).



2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



3. REMOVE FAN AND GENERATOR V BELT


    A217571
  1. While turning the belt tensioner counterclockwise, align the service hole for the belt tensioner and the belt tensioner fixing position, and then insert a bar of 6 mm (0.236 in.) into the service hole to fix the belt tensioner in place.

    HINT:
    The pulley bolt for the belt tensioner has a left-hand thread.

  1. Remove the V belt.



4. REMOVE NO. 2 IDLER PULLEY SUB-ASSEMBLY


    A223415
  1. for Integrated Type:
    Remove the bolt and No. 2 idler pulley.

  1. for Separate Type:
    Remove the bolt, No. 2 idler pulley cover plate, No. 2 idler pulley and idler pulley cover plate.



5. REMOVE FRONT FENDER APRON SEAL REAR LH
  1. Remove the 5 clips and fender apron seal.



6. REMOVE NO. 2 EXHAUST MANIFOLD HEAT INSULATOR


    A237699
  1. Remove the 3 bolts and heat insulator.



7. REMOVE GENERATOR ASSEMBLY


    A237638
  1. Remove the bolt and disconnect the wire harness bracket.



    A238033
  1. Open the terminal cap.

  1. Remove the nut and disconnect the wire harness from terminal B.

  1. Disconnect the generator connector from the generator assembly.



    A237639
  1. Disconnect the wire harness clamp.

  1. Remove the bolt and disconnect the generator bracket.



    A237640
  1. Remove the 2 bolts and generator assembly.



    A222885
  1. Remove the bolt and generator bracket.