DTC No.
| Monitoring Item
| Malfunction Detection Condition
| Trouble Area
| Detection Timing
| Detection Logic
|
P043E
| Reference orifice clogged
| P043E, P043F, P2401, P2402 and P2419 are stored when one of the following conditions is met during the key-off EVAP monitor:
- Reference orifice clogged
- Reference orifice high flow
- Leak detection pump OFF malfunction
- Leak detection pump ON malfunction
- Vent valve ON (closed) malfunction
| - Canister pump module
- Connector/wire harness (Canister pump module - ECM)
- ECM
| While ignition switch off
| 2 trip
|
P043F
| Reference orifice high flow
|
P2401
| Leak detection pump stuck OFF
|
P2402
| Leak detection pump stuck ON
|
P2419
| Vent valve stuck closed
|
Sequence
| Operation
| Description
| Duration
|
-
| ECM activation
| Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off.
| -
|
A
| Atmospheric pressure measurement
| Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure. If pressure in EVAP system not between 70 kPa-a and 110 kPa-a (525 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
| 60 seconds
|
B
| First reference pressure measurement
| In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice, and then ECM checks if leak detection pump and vent valve operate normally.
| 360 seconds
|
C
| EVAP system pressure measurement
| Vent valve turned ON (closed) to shut EVAP system. Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured. Write down measured value as it will be used in leak check. If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
| 15 minutes*
|
D
| Purge VSV monitor
| Purge VSV opened, and then EVAP system pressure measured by ECM. Large increase indicates normality.
| 10 seconds
|
E
| Second reference pressure measurement
| After second reference pressure measurement, leak check performed by comparing first and second reference pressure measurements. If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
| 60 seconds
|
-
| Final check
| Atmospheric pressure measured, and then monitoring result recorded by ECM.
| -
|
Monitor runs whenever following DTCs not stored
| P0452, P0453 (EVAP System)
|
Atmospheric pressure
| 70 to 110 kPa-a (525 to 825 mmHg-a)
|
Battery voltage
| 10.5 V or higher
|
Vehicle speed
| Less than 4 km/h (2.5 mph)
|
Ignition switch
| OFF
|
Time after key-off
| 5, 7 or 9.5 hours
|
Purge VSV
| Not operated by scan tool
|
Vent valve
| Not operated by scan tool
|
Leak detection pump
| Not operated by scan tool
|
Both of following conditions met before key-off
| Conditions 1 and 2
|
1. Duration that vehicle driven
| 5 minutes or more
|
2. EVAP purge operation
| Performed
|
Engine coolant temperature
| 4.4 to 35°C (40 to 95°F)
|
Intake air temperature
| 4.4 to 35°C (40 to 95°F)
|