Home › ENGINE ยท 3UR-FE › CHARGING › GENERATOR

GENERATOR > INSTALLATION

for Preparation Click here



1. INSTALL GENERATOR ASSEMBLY


    A156406
  1. Install the generator with the 3 bolts and nut.

    Torque:
    43 N*m{ 439 kgf*cm , 32 ft.*lbf }



    A156405
  1. Connect the generator connector.

  1. Connect the generator wire with the nut.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }

  1. Install the terminal cap.

  1. Install the harness bracket to the generator with the bolt.

    Torque:
    31 N*m{ 316 kgf*cm , 23 ft.*lbf }



2. CONNECT VANE PUMP ASSEMBLY


A163333E05

HINT:
Before performing the following procedures, move the spacer until the vane pump assembly can be installed.
Text in Illustration 
*a
Spacer

  1. Connect the vane pump assembly to the timing chain cover sub-assembly with the 2 bolts.

    Torque:
    28 N*m{ 286 kgf*cm , 21 ft.*lbf }



3. INSTALL FRONT FENDER APRON SEAL RH
  1. Install the apron seal with the 5 clips.



4. INSTALL FAN AND GENERATOR V BELT


    A163771E01
  1. Set the V belt onto every part.

  1. While turning the belt tensioner counterclockwise, remove the pin.

    NOTICE:
    Make sure that the V belt is properly set to each pulley.



    A174124E01
  1. After installing the belt, check that it fits properly in the ribbed grooves.

    HINT:
    Make sure to check by hand that the belt has not slipped out of the grooves on the bottom of the pulley.



5. INSTALL NO. 1 ENGINE UNDER COVER SUB-ASSEMBLY


    A150108
  1. Hook the engine under cover to the vehicle body as shown in the illustration.

  1. Install the 3 screws and 5 bolts.

    Torque:
    for bolt:
    29 N*m{ 296 kgf*cm , 21 ft.*lbf }
    for screw:
    5.4 N*m{ 55 kgf*cm , 48 in.*lbf }



6. INSTALL AIR CLEANER ASSEMBLY


    A309638E01
  1. Install the air cleaner case with the 2 bolts.

    Torque:
    5.0 N*m{ 51 kgf*cm , 44 in.*lbf }

  1. Install the air cleaner element onto the air cleaner case.



    A309637E01
  1. Install the air cleaner cap.

    1. for Type A:
      Install the air cleaner cap and fasten the 4 hook clamps.

    2. for Type B:
      Install the air cleaner cap and fasten the 2 hook clamps.

    3. Connect the MAF meter connector.

    4. Attach the wire harness clamp.



7. INSTALL AIR CLEANER HOSE ASSEMBLY


    A162102
  1. Install the air cleaner hose with the 2 clamps.

    Torque:
    4.0 N*m{ 41 kgf*cm , 35 in.*lbf }

  1. Connect the vacuum hose.

  1. Connect the ventilation hose.



8. INSTALL V-BANK COVER


    A165576E02
  1. Attach the 2 V-bank cover hooks to the bracket. Then align the 2 V-bank cover grommets with the 2 pins, and press down on the V-bank cover to attach the pins.



9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL