Home › ENGINE ยท 1GR-FE › EXHAUST › EXHAUST PIPE

EXHAUST PIPE > INSTALLATION

for Preparation Click here


HINT:
If an exhaust gas leak has been repaired, perform an inspection following the repair (Click here).



1. INSTALL FRONT EXHAUST PIPE ASSEMBLY
  1. Install a new gasket and the front exhaust pipe assembly to the exhaust manifold sub-assembly RH with 3 new nuts.

    Torque:
    54 N*m{ 554 kgf*cm , 40 ft.*lbf }



2. INSTALL FRONT NO. 2 EXHAUST PIPE ASSEMBLY
  1. Connect the front No. 2 exhaust pipe assembly to the exhaust pipe support.

  1. Install a new gasket and the front No. 2 exhaust pipe assembly to the exhaust manifold sub-assembly LH with 3 new nuts.

    Torque:
    54 N*m{ 554 kgf*cm , 40 ft.*lbf }



3. INSTALL CENTER EXHAUST PIPE ASSEMBLY
  1. Connect the center exhaust pipe assembly to the 3 exhaust pipe supports.

  1. Install 2 new gaskets to the front exhaust pipe assembly and front No. 2 exhaust pipe assembly.

  1. Install the center exhaust pipe assembly with the 4 bolts.

    Torque:
    48 N*m{ 489 kgf*cm , 35 ft.*lbf }



4. INSTALL TAILPIPE ASSEMBLY
  1. Connect the tailpipe assembly to the exhaust pipe support.

  1. Install a new gasket to the center exhaust pipe assembly.



    A236957E03
  1. Attach a new clamp to the tailpipe assembly and center exhaust pipe assembly. Then install the bolt to the clamp.

    Torque:
    32 N*m{ 326 kgf*cm , 24 ft.*lbf }

    HINT:
    Install the clamp within the angle range shown in the illustration.

    Text in Illustration 
    *a
    Top
    *b
    LH Side of Vehicle
    *c
    Front Side of Vehicle



5. INSTALL AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)


    A240681E01
  1. Using SST, install the sensor.

    SST
    09224-00010  

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    Text in Illustration 
    *a
    Fulcrum Length

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.
    3. Perform "Inspection After Repairs" after replacing the air fuel ratio sensor (Click here).

  1. Connect the connector.



6. INSTALL AIR FUEL RATIO SENSOR (for Bank 2 Sensor 1)


    A240679E01
  1. Using SST, install the sensor.

    SST
    09224-00010  

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    Text in Illustration 
    *a
    Fulcrum Length

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.
    3. Perform "Inspection After Repairs" after replacing the air fuel ratio sensor (Click here).

  1. Connect the connector.



7. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)


    A240675E01
  1. Using SST, install the sensor.

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    Text in Illustration 
    *a
    Fulcrum Length

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.
    3. Perform "Inspection After Repairs" after replacing the Perform "Inspection After Repairs" after replacing the heated oxygen sensor (Click here).

  1. Connect the connector and 2 clamps.



8. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)


    A240677E01
  1. Using SST, install the sensor.

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    Text in Illustration 
    *a
    Fulcrum Length

    HINT:
    1. Use a torque wrench with a fulcrum length of 30 cm (11.8 in.). If using a torque wrench with a length that is not 30 cm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification (Click here).
    2. Make sure SST and wrench are connected in a straight line.
    3. Perform "Inspection After Repairs" after replacing the Perform "Inspection After Repairs" after replacing the heated oxygen sensor (Click here).

  1. Connect the connector.



9. INSPECT FOR EXHAUST GAS LEAK

HINT:
If an exhaust gas leak has been repaired, perform an inspection following the repair (Click here).

If gas is leaking, tighten the areas necessary to stop the leak. Replace damaged parts as necessary.