Home › DRIVE LINE › WF1AM TRANSFER › TRANSFER ASSEMBLY

TRANSFER ASSEMBLY > INSPECTION

for Preparation Click here



1. INSPECT OUTPUT SHAFT COMPANION FLANGE SUB-ASSEMBLY (FRONT)


    C291202E01
  1. Using a micrometer, measure the outer diameter of the output shaft companion flange sub-assembly (front) journal surface.

    Minimum Diameter:
    Journal
    Specified Condition
    A
    34.962 mm (1.376 in.)
    B
    39.955 mm (1.573 in.)

    If the outer diameter is less than the minimum, replace the output shaft companion flange sub-assembly (front).



2. INSPECT TRANSFER LOW PLANETARY GEAR ASSEMBLY


    C291203
  1. Using a feeler gauge, measure the thrust clearance of the pinion gear.

    Maximum clearance:
    0.93 mm (0.037 in.)

    If the clearance is more than the maximum, replace the transfer low planetary gear assembly.



    C291204
  1. Using a dial indicator, measure the radial clearance of the pinion gear.

    Maximum clearance:
    0.021 mm (0.0008 in.)

    If the clearance is more than the maximum, replace the transfer low planetary gear assembly.



3. INSPECT REAR TRANSFER OUTPUT SHAFT


    C291205E01
  1. Using a micrometer, measure the diameter of the rear transfer output shaft journal.

    Minimum Diameter:
    Journal
    Specified Condition
    A
    29.987 mm (1.181 in.)
    B
    34.848 mm (1.372 in.)
    C
    58.000 mm (2.284 in.)
    D
    49.110 mm (1.934 in.)
    E
    44.874 mm (1.767 in.)

    If the diameter is less than the minimum, replace the rear transfer output shaft.



4. INSPECT SOLENOID LOCK PLATE AND NO. 2 TRANSFER GEAR SHIFT FORK CLEARANCE


    C291206E01
  1. Using a vernier caliper, measure the thickness of the No. 2 transfer gear shift fork claw.

    Standard thickness (A):
    6.90 to 7.06 mm (0.272 to 0.277 in.)

  1. Using a vernier caliper, measure the width of the groove of the solenoid lock plate.

    Standard width (B):
    7.16 to 7.32 mm (0.282 to 0.288 in.)

  1. Calculate the clearance between the solenoid lock plate and No. 2 transfer gear shift fork claw.

    Maximum clearance (B) - (A):
    0.42 mm (0.017 in.)

    If the clearance is more than the maximum, replace the solenoid lock plate or No. 2 transfer gear shift fork.



5. INSPECT NO. 1 TRANSFER GEAR SHIFT FORK AND NO. 2 TRANSFER GEAR SHIFT FORK


    C291207
  1. Check the gear shift fork pad for wear or damage.
    If necessary, replace the gear shift fork pad.



    C291209E01
  1. Using a micrometer, measure the outer diameter of the No. 1 transfer gear shift fork and No. 2 transfer gear shift fork.

    Minimum Diameter:
    Diameter
    Specified Condition
    A
    12.586 mm (0.496 in.)
    B
    12.586 mm (0.496 in.)

    Text in Illustration 
    *1
    No. 1 Transfer Gear Shift Fork
    *2
    No. 2 Transfer Gear Shift Fork
    If the diameter is less than the minimum, replace the No. 1 transfer gear shift fork or No. 2 transfer gear shift fork.



6. INSPECT TRANSFER HIGH AND LOW CLUTCH SLEEVE


    C291208
  1. Using a vernier caliper, measure the thickness of the transfer high and low clutch sleeve.

    Minimum thickness:
    3.00 mm (0.1182 in.)

    If the thickness is less than the minimum, replace the transfer high and low clutch sleeve.



7. INSPECT TRANSFER OUTPUT SHAFT SPACER


    C291210
  1. Using a vernier caliper, measure the thickness of the No. 1 transfer output shaft spacer and No. 2 transfer output shaft spacer.

    Minimum Thickness:
    Transfer Output Shaft Spacer
    Minimum Thickness
    No. 1 Transfer Output Shaft Spacer
    2.80 mm (0.111 in.)
    No. 2 Transfer Output Shaft Spacer
    4.045 mm (0.160 in.)

    If the thickness is less than the minimum, replace the transfer output shaft spacer.



8. INSPECT SOLENOID COIL SUB-ASSEMBLY


    C291151E01
  1. Install the solenoid coil sub-assembly with the 3 nuts.

    Torque:
    9.5 N*m{ 97 kgf*cm , 84 in.*lbf }

    Text in Illustration 
    *a
    Rear Transfer Case Hole
    Make sure that the solenoid coil sub-assembly terminal extends out from the rear transfer case hole.

  1. Connect the solenoid coil sub-assembly terminal.



  1. Measure the resistance according to the value(s) in the table below.


    C291226E01

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (SCC) - Case GND
    Always
    1.62 to 1.78 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Solenoid Coil Sub-assembly)
    *b
    Case GND

    HINT:
    For case ground, perform the measurement at one of the locations indicated by the arrows.