Home › ENGINE ยท 1UR-FE › EMISSION CONTROL › CANISTER

CANISTER > INSTALLATION

for Preparation Click here



1. INSTALL CANISTER PUMP MODULE


    A263356
  1. Engage the 2 claws to install a new canister pump module to the charcoal canister assembly.

    NOTICE:
    1. Do not allow foreign matter such as grease, oil or water to adhere to the O-rings.
    2. Ensure that the claws are engaged properly.



2. INSTALL CHARCOAL CANISTER ASSEMBLY
  1. Install the charcoal canister assembly with the 4 bolts.

    Torque:
    29 N*m{ 296 kgf*cm , 21 ft.*lbf }

  1. Attach the wire harness clamp.



    A273953E01
  1. Connect the vent line hose.

    1. Push the vent line hose into the port and push the retainer to lock it.
      Text in Illustration 
      *1
      Vent Line Hose
      *2
      Retainer
      V100136
      Push

      NOTICE:
      1. Check for damage or foreign objects on the connected part.
      2. After connecting the vent line hose, check that the vent line hose and valve are securely connected by pulling on them.

  1. Connect the air inlet line hose.

    NOTICE:
    1. Check for damage or foreign objects on the connected part.
    2. After connecting the air inlet line hose, check that the air inlet line hose and valve are securely connected by pulling on them.

  1. Connect the purge line hose and slide the clamp to secure the hose.

  1. Connect the canister pump module connector.

  1. Connect the wiring harness clamp bracket with the nut.

    Torque: