CANISTER > REMOVAL |
| 1. REMOVE CHARCOAL CANISTER ASSEMBLY |
![]() |
Remove the nut and disconnect the wiring harness clamp bracket.
![]() |
Disconnect the canister pump module connector.
| *1 | Vent Line Hose |
| *2 | Air Inlet Line Hose |
| *a | Charcoal Canister Assembly Side |
| *b | Retainer |
![]() | Upper |
![]() | Pinch |
Slide the clamp and disconnect the purge line hose.
Disconnect the air inlet line hose.
Push the air inlet line hose firmly toward the charcoal canister assembly.
Pinch the air inlet line hose as shown in the illustration.
Pull out the air inlet line hose.
Disconnect the vent line hose.
Pinch the retainer and raise it.
![]() |
Detach the wire harness clamp.
![]() |
Remove the 4 bolts and charcoal canister assembly.
| 2. REMOVE CANISTER PUMP MODULE |
Before removing the canister pump module, clean the charcoal canister assembly by blowing air into it to ensure that the charcoal canister assembly is free of foreign matter.
![]() |
While disengaging the 2 claws as shown in the illustration, push the canister pump module upwards using a screwdriver to remove it.
Check if the charcoal canister contains foreign matter such as mud or water.
![]() |
Visually check that the inside of the charcoal canister assembly is free of foreign matter.
Hold the charcoal canister assembly upside down to make sure that the charcoal canister assembly is free of foreign matter.
If the charcoal canister assembly contains foreign matter, replace the charcoal canister assembly.