Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 3UR-FBE FUEL

3UR-FBE FUEL > SERVICE DATA



Fuel pressure 
at idle
Fuel flow when the fuel pressure switching valve is off
270 to 330 kPa
(2.75 to 3.37 kgf/cm2, 39.2 to 47.9 psi)
Fuel flow when the fuel pressure switching valve is on
370 to 430 kPa
(3.77 to 4.38 kgf/cm2, 53.7 to 62.4 psi)
remains for 5 minutes after engine has stopped
147 kPa
(1.5 kgf/cm2, 21 psi) or more

Fuel injector 
Resistance: at 20°C (68°F)
11.6 to 12.4 Ω
Injection volume
97 to 118 cm3 (5.9 to 7.2 cu in.) per 15 seconds
Difference between each cylinder
21 cm3 (1.3 cu in.) or less
Fuel leakage
1 drop or less per 12 minutes

Fuel pressure switching valve 
Tester Connection
Condition
Specified Condition
1 - Body ground
Always
10 MΩ or higher
2 - Body ground
1 - 2
20°C (68°F)
5 to 10 Ω

Fuel pump 
Tester Connection
Condition
Specified Condition
4 - 5
20°C (68°F)
0.2 to 3.0 Ω

Fuel sender gauge 
Tester Connection
Condition
Specified Condition
2 - 4
Float level is F (upper)
111 to 119 Ω
Float level is E (lower)
506 to 514 Ω