Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 3UR-FE CHARGING

3UR-FE CHARGING > SERVICE DATA



Battery
Standard specific gravity
1.25 to 1.29 at 20°C (68°F)
Charging circuit without load
Standard amperage
10 A or less
Standard voltage
13.2 to 14.8 V
(when engine speed at 2000 rpm)
Charging circuit with load
Standard amperage
30 A or more
Generator rotor
Standard resistance
between the slip rings
100 A Type and 130 A Type
2.3 to 2.7 Ω at 20°C (68°F)
between the slip rings
150 A Type
1.5 to 1.9 Ω at 20°C (68°F)
between the slip ring and rotor
10 kΩ or higher
Standard diameter
14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter
14.0 mm (0.551 in.)
Generator brush holder
Standard exposed length
10.5 mm (0.413 in.)
Minimum exposed length
4.5 mm (0.177 in.)