Home › ENGINE · 3UR-FBE › ENGINE CONTROL SYSTEM › CAMSHAFT OIL CONTROL VALVE

CAMSHAFT OIL CONTROL VALVE > INSPECTION

for Preparation Click here



1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY


    A165596E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    6.9 to 7.9 Ω

    If the result is not as specified, replace the oil control valve assembly.



    A165597E02
  1. Connect the battery's positive (+) lead to terminal 1 and the negative (-) lead to terminal 2, and check the movement of the valve.

    OK:
    Condition
    Specified Condition
    Battery positive (+) voltage is applied
    Valve moves in left arrow direction shown in the illustration
    Battery positive (+) voltage is cut off
    Valve moves in right arrow direction shown in the illustration

    If the result is not as specified, replace the oil control valve assembly. If the valve cannot return properly because of foreign matter, a small pressure leak in the advanced direction may occur and a DTC may be output.