Home › ENGINE ยท 1UR-FE › COOLING › WATER PUMP

WATER PUMP > INSTALLATION

for Preparation Click here



1. INSTALL WATER PUMP ASSEMBLY


    A215872E01
  1. Install a new gasket and the water pump assembly with the 8 bolts shown in the illustration.

    Torque:
    for bolt A:
    47 N*m{ 479 kgf*cm , 35 ft.*lbf }
    for bolt B:
    23 N*m{ 235 kgf*cm , 17 ft.*lbf }
    for bolt C:
    20 N*m{ 204 kgf*cm , 15 ft.*lbf }



2. INSTALL WATER PUMP PULLEY
  1. Temporarily install the water pump pulley with the 4 bolts.



    A210018E02
  1. Using SST, hold the water pump pulley and tighten the 4 bolts.

    SST
    09960-10010   (09962-01000, 09963-01000)

    Torque:
    21 N*m{ 214 kgf*cm , 15 ft.*lbf }



3. INSTALL WATER INLET HOUSING
  1. Install a new gasket to the water pump assembly.



    A215871
  1. Install the water inlet housing with the 3 bolts.

    Torque:
    21 N*m{ 214 kgf*cm , 15 ft.*lbf }



4. CONNECT NO. 5 WATER BY-PASS HOSE


    A215870E01
  1. Connect the No. 5 water by-pass hose.

    HINT:
    The direction of hose clamp is indicated in the illustration.



5. CONNECT NO. 8 WATER BY-PASS HOSE


    A215868E01
  1. Connect the No. 8 water by-pass hose.

    HINT:
    The direction of hose clamp is indicated in the illustration.



6. INSTALL NO. 1 WATER BY-PASS HOSE


    A215866E01
  1. Install the No. 1 water by-pass hose.

    HINT:
    The direction of hose clamp is indicated in the illustration.



7. INSTALL WATER INLET SUB-ASSEMBLY WITH THERMOSTAT
(Click here)


8. INSTALL FAN SHROUD
(Click here)