Home › BODY ELECTRICAL › LIGHTING › HAZARD WARNING SWITCH

HAZARD WARNING SWITCH > INSPECTION

for Preparation Click here



1. INSPECT AIR CONDITIONING CONTROL ASSEMBLY (HAZARD WARNING SWITCH)


E281402E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 (HAZ) - 5 (GND)
    Hazard warning switch off
    10 kΩ or higher
    Hazard warning switch on
    Below 1 Ω

    If the result is not as specified, replace the air conditioning control assembly (hazard warning switch).
    Text in Illustration 
    *a
    Component without harness connected
    (Air Conditioning Control Assembly (Hazard Warning Switch))