GLASS BREAKAGE SENSOR (for Column Shift Type) > INSTALLATION |
| 1. INSTALL GLASS BREAKAGE SENSOR MICROPHONE |
Attach the 2 claws to install the glass breakage sensor microphone.
| 2. INSTALL AIR CONDITIONING CONTROL ASSEMBLY |
Put protective tape around the air conditioning control assembly.

| *A | for Automatic Air Conditioning System | *B | for Manual Air Conditioning System |
| *1 | Protective Tape | *2 | Air Conditioning Control Assembly |
| *3 | Center Lower Instrument Panel Finish Panel | - | - |
Using moulding remover B, detach the 8 clips, 2 claws and guide.
Disconnect each connector and remove the air conditioning control assembly together with the center lower instrument panel finish panel.
![]() |
Detach the 3 clips and remove the air conditioning control assembly from the center lower instrument panel finish panel.
| *1 | Air Conditioning Control Assembly |
| *2 | Center Lower Instrument Panel Finish Panel |
| 3. INSTALL CENTER LOWER INSTRUMENT COVER |
Attach the 2 guides and 2 clips to install the lower center instrument cover.
Install the 2 clips.