Home › BODY ELECTRICAL › LIGHTING › AUTOMATIC LIGHT CONTROL SENSOR

AUTOMATIC LIGHT CONTROL SENSOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR


E139361E09
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    6 (CLTB) - 3 (CLTE)
    Ignition switch ON
    11 to 14 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    3 (CLTE) - Body ground
    Always
    Below 1 Ω

  1. Reconnect the automatic light control sensor connector.



    E163473E01
  1. Check the waveform of the automatic light control sensor connector.

    Waveform:
    Tester Connection
    Tool Setting
    Switch Condition
    Specified Condition
    3 (CLTE) - 5 (CLTS)
    5 V/DIV., 5 msec./ DIV.
    Ignition switch ON, headlight dimmer switch on AUTO
    Correct waveform is as shown

    HINT:
    If the ambient light becomes brighter, width A becomes narrower.
    If the result is not as specified, there may be a malfunction in the automatic light control sensor.
    Text in Illustration 
    *a
    Component with harness connected
    (Automatic Light Control Sensor)