Home › BODY ELECTRICAL › LIGHTING › LIGHTING SYSTEM

LIGHTING SYSTEM > Hazard Warning Switch Circuit

for Preparation Click here


DESCRIPTION

The turn signal flasher receives a hazard warning signal switch information signal, and illuminates the turn signal lights.

WIRING DIAGRAM


E146720E14


INSPECTION PROCEDURE

1.INSPECT AIR CONDITIONING CONTROL ASSEMBLY
E280455E01
  1. Remove the air conditioning control (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - 5
    Hazard warning switch ON
    Below 1 Ω
    Hazard warning switch OFF
    10 kΩ or higher



NG
REPLACE AIR CONDITIONING CONTROL ASSEMBLY (Click here)
OK


2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING CONTROL ASSEMBLY - TURN SIGNAL FLASHER AND BODY GROUND)

E280456E01

  1. Disconnect the J127 switch connector.

  1. Disconnect the J29 relay connector.

  1. Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection
Condition
Specified Condition
J127-1 - J29-12 (HAZ)
Always
Below 1 Ω
J127-1 - Body ground
J127-5 - Body ground
Always
10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)