Home › BODY ELECTRICAL › PARK ASSIST / MONITORING › CLEARANCE WARNING ECU

CLEARANCE WARNING ECU > INSTALLATION

for Preparation Click here


HINT:
A bolt without a torque specification is shown in the standard bolt chart (Click here).



1. INSTALL CLEARANCE WARNING ECU ASSEMBLY


    B354802
  1. Install the clearance warning ECU assembly to the bracket with the 2 nuts.

    NOTICE:
    1. Avoid any impact to the clearance warning ECU assembly.
    2. Do not drop the ECU. If it is dropped, replace it with a new one.



2. INSTALL CLEARANCE WARNING ECU WITH BRACKET


    B354801
  1. Install the clearance warning ECU with bracket with the nut and bolt.

  1. Connect the ECU connectors and attach the harness clamp.

    NOTICE:
    Do not apply excessive force to the wire harnesses.



3. INSTALL LOWER INSTRUMENT PANEL FINISH PANEL SUB-ASSEMBLY RH


    B355352
  1. Attach the 4 claws to install the lower instrument panel finish panel sub-assembly RH.

  1. Install the 4 screws <F> and bolt <A>.



4. INSTALL NO.2 INSTRUMENT CLUSTER FINISH PANEL GARNISH


    B355354
  1. Attach the 3 claws and 4 clips to install the No. 2 instrument cluster finish panel garnish.



5. INSTALL INSTRUMENT SIDE PANEL RH


    B355356
  1. Attach the 4 guides and 3 claws to install the instrument side panel RH.



6. INSTALL NO.4 INSTRUMENT REGISTER SUB-ASSEMBLY


B355349
  1. Attach the 10 clips to install the No. 4 instrument register sub-assembly.



7. INSTALL LOWER NO. 2 INSTRUMENT PANEL AIRBAG ASSEMBLY


    B226008
  1. Connect the connector.

    NOTICE:
    When handling the airbag connector, take care not to damage the airbag wire harness.

  1. Install the 3 bolts to install the instrument panel airbag.

    Torque:
    10 N*m{ 102 kgf*cm , 7 ft.*lbf }



8. INSTALL LOWER INSTRUMENT PANEL
  1. Attach the 3 claws to install the lower instrument panel.

  1. Install the bolt <A> and screw <D>.



9. INSTALL NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY
  1. Attach the 2 guides, 4 claws and clip to install the No. 2 instrument panel under cover sub-assembly.



10. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



11. CHECK SRS WARNING LIGHT
  1. Check the SRS warning light .