Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > CUSTOMIZE PARAMETERS

for Preparation Click here



CUSTOMIZING FUNCTION WITH TECHSTREAM

NOTICE:
  1. When the customer requests a change in a function, first make sure that the function can be customized.
  2. Be sure to make a note of the current settings before customizing.
  3. When troubleshooting a function, first make sure that the function is set to the default setting.

  1. Connect the Techstream to the DLC3.

  2. Turn the ignition switch ON.

  3. Turn the Techstream on.

  4. Enter the following menus: Customize Setting.

  5. Select the setting by referring to the table below.

    Air Conditioner 
    Display
    Default
    Contents
    Setting
    Set Temperature Shift
    Normal
    Function to control the shifted temperature in relation to the displayed temperature
    +2 C / +1 C / Normal / -1 C / -2 C
    Air Inlet Mode
    Automatic
    In case of turning the A/C ON to cool down the cabin quickly, this is the function to change the mode automatically to RECIRCULATION mode
    Manual / Automatic
    Compressor Mode
    Automatic
    Function to turn the A/C ON automatically by pressing the AUTO button when the blower is ON and the A/C is OFF
    Manual / Automatic
    Compressor/Air Inlet DEF operation
    Link
    Function to turn the A/C ON automatically linked with the FRONT DEF button when A/C is OFF
    Normal / Link
    Foot/DEF Auto Mode
    ON
    Function to turn the airflow from FOOT / DEF ON automatically when AUTO MODE is ON
    OFF / ON
    Foot/DEF Automatic Blow Up Function
    ON
    Function to change the blower level automatically when the defroster is ON
    OFF / ON
    Ambient Temperature Shift
    Normal
    Function to control the shifted ambient temperature in relation to the displayed ambient temperature
    +3 C / +2 C / +1 C / Normal / -1 C / -2 C / -3 C
    Add Foot Air in FACE Mode
    ON
    When the FACE mode is selected, an additional amount of air blow to the foot area. Selecting OFF will cancel this additional air flow.
    OFF / ON