Home › BODY ELECTRICAL › HORN › LOW PITCHED HORN

LOW PITCHED HORN > INSPECTION

for Preparation Click here



1. INSPECT LOW PITCHED HORN ASSEMBLY


B349198E01
  1. Apply battery voltage and check operation of the low pitched horn assembly, as shown in the table.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → Terminal 1
    Battery negative (-) → Body ground
    Low pitched horn assembly sounds

    If the result is not as specified, replace the low pitched horn assembly.